Heat stress measurement for ramp crews and condition, level and position sensing on ground support equipment, so a failure happens in the workshop rather than against an aircraft on a stand.

WBGT
How heat stress is assessed, not air temperature
2
Debris classes, fine and coarse, reported separately
IP67
Blade position sensors, IP67 for temporary immersion
0
Moving parts in a capacitive level sensor

Everything on the ramp happens against a clock

A stand turnaround is a sequence of dependent tasks with an aircraft at the end of it, and there is no slack designed into any of them. Equipment that fails on the stand does not cost a repair, it costs a departure.

The crews doing the work are outside through the hottest and coldest parts of the day, in high-visibility clothing, next to running engines and hot surfaces. Air temperature does not describe what they are exposed to, which is why heat stress is assessed as WBGT.

The equipment itself wears in ways that are visible well before they are disruptive. Oil picks up ferrous debris, fluid levels fall, and actuator positions drift, all of it measurable and most of it currently found at a service interval.

Airport sensing map

Every airfield decision starts at a measurement point

An airport measures across the whole estate. Surface wind along the runway. Temperature, humidity and precipitation for approach and de-icing. Heat stress and machinery condition on the apron.

Explore 17 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need WBGT configuration, fitting options or integration detail?Heat stress measurement, sump plug and bypass arrangements, mounting and output formats. Direct from our engineering team.

Request information

Two different problems sharing one apron

Heat stress is a people problem measured environmentally. Wet bulb globe temperature combines air temperature, humidity, radiant heat and air movement into the single index that working limits are actually written against, and it can differ substantially from the air temperature on the same apron.

Radiant heat is the part that a thermometer misses entirely. An apron is a large area of dark surface next to aircraft that have just landed, and the globe temperature reflects that in a way a screen reading never will.

Ground support equipment is an engineering problem measured mechanically. Tugs, loaders, belt units, steps and de-icing rigs all carry oil-lubricated drives, hydraulic and fuel tanks, and actuators whose position matters to the machine and sometimes to the aircraft next to it.

Both are worth measuring for the same reason: the alternative is finding out on the stand, and the stand is the most expensive place on the airfield to find out anything.

WBGT is the index the limits are written against

Working limits, rest schedules and hydration guidance are written against wet bulb globe temperature rather than air temperature, because WBGT accounts for humidity, radiant heat and air movement as well.

MaxiMet provides WBGT measurement alongside the rest of the meteorological set, so the assessment comes from the apron the crews are working on rather than from a nearby reference station or a forecast.

Measured on the apron, not nearby

View heat stress measurement

Find it in the workshop, not on the stand

Equipment that fails against an aircraft creates a delay, a recovery and a stand out of service. The same failure found during a scheduled check is a parts order.

WearDetect monitors ferrous debris in oil, reporting fine and coarse separately alongside water presence and oil temperature. Capacitive level sensing covers fuel, oil and hydraulic tanks with no float, and the Blade range provides non-contact position feedback sealed to IP67.

A scheduled swap beats a delayed departure

View WearDetect

Both of these get reviewed

Heat stress management is reviewed as a duty of care matter, and it is reviewed against what was measured rather than against what the forecast said. A local WBGT record is the difference between a policy and evidence that it was applied.

Equipment reliability is reviewed commercially. Delay attribution, fleet replacement cases and maintenance contracts all work from failure history, and condition data turns that history into something that can be acted on in advance.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer, which keeps the apron instruments and the workshop instruments on one schedule.

What the apron and its equipment measure

Heat stress and conditions for the crews, and condition, level and position sensing for the equipment that keeps stands turning.

Crew and conditions

Gill MaxiMet compact weather stations
Heat stress

MaxiMet

All-in-one weather station, no moving parts

WBGT alongside wind, temperature, humidity, pressure, solar radiation and rainfall, measured on the apron itself.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Gill WindSonic ultrasonic anemometers
Ramp wind

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight wind measurement for stand and equipment operating limits, mounted without a structural conversation.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Gill TruMet PW100 optical rain gauge
Precipitation

TruMet PW100

Infrared optical rain gauge

Optical rainfall measurement for ramp working conditions and surface decisions, with no mechanism to block.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Output : One pulse per 0.1 mm, replicating a tipping bucket
Build : No moving mechanism to block or seize

View TruMet PW100

Ground support equipment

Gill WearDetect oil debris sensors
Condition

WearDetect

Oil debris sensor

Ferrous debris in engine, transmission and hydraulic oil on tugs, loaders and belt units, reported while the component is still a component.

Measures : Fine and coarse ferrous debris, water presence, oil temperature
Outputs : 0-10 V, 4-20 mA, CANbus or Modbus RTU
Fitting : Smart sump-plug replacement or bypass circuit

View WearDetect

Gill capacitive liquid level sensors
Fluids

Level sensing

Capacitive liquid level sensors

Fuel, oil, hydraulic and coolant level with no float to jam on equipment that spends its day moving and vibrating.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Gill Blade non-contact position sensors
Position

Blade position sensors

Non-contact inductive position sensing

Non-contact position feedback for lift, boom and platform mechanisms working close to an aircraft.

Linear : Blade25 measures 25 mm, Blade60 measures 60 mm, both configurable
Rotary : Blade360 measures a full 360 degrees and is sealed to IP67 for temporary immersion
Sealing : IP67 across the range, sealed for temporary immersion (1 m for 30 min)

Explore position sensors

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where apron and GSE measurement does the work

Ramp crews

Heat stress management

WBGT measured on the apron, supporting working limits and the record that they were applied.

Tugs and tractors

Drivetrain condition

Ferrous debris trending on the equipment whose failure blocks a stand.

Belt and container loaders

Position and hydraulics

Non-contact position feedback and hydraulic level on equipment working against an aircraft.

Passenger steps and bridges

Mechanism feedback

Position measurement on mechanisms that have to stop accurately and repeatably.

De-icing rigs

Seasonal availability

Condition and level monitoring on equipment that has to work on the first freezing morning.

Fleet management

Planned intervention

Condition data across a GSE fleet, so workshop time is booked against evidence.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For an apron estate carrying anemometers, thermal probes, pressure instruments, thermometers, temperature and humidity probes and data loggers, a single accredited laboratory keeps everything on one traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting both measurements where they are used

Heat stress information is acted on by supervisors on the apron, and equipment condition is acted on by a workshop planner. The same installation has to serve two different audiences.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so handling agents, airport operators and GSE manufacturers can bring both into existing systems.

Whether the requirement is CANbus into a vehicle network, Modbus into a fleet system, a serial string into an operational display, or a configurable sensor embedded into an OEM build, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • CANbus & RS232 : Vehicle networks and telematics
  • Modbus RTU : Fleet and site systems
  • 4-20 mA & 0-10 V : Existing analogue channels
  • BladeCom : Travel, switch points and output limits set before fitting

What the specification looks like in practice

01

WBGT rather than air temperature

Heat stress limits are written against wet bulb globe temperature, which accounts for humidity, radiant heat and air movement.

02

Measured where the work happens

An apron reading describes the apron, which a nearby reference station and a forecast do not.

03

Wear found before the stand

Fine and coarse ferrous debris reported separately, so a failing component is visible while it is still a component.

04

No float in a moving tank

Capacitive level sensing has no mechanical float on equipment that spends its day accelerating, braking and turning.

05

Position without a wear item

Blade sensors measure across a gap to a passive activator, sealed to IP67 for temporary immersion (1 m for 30 min).

06

Into the systems already running

CANbus, Modbus, analogue and serial outputs reach vehicle networks, fleet systems and operational displays.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about apron and ground support equipment

Heat stress, condition and position

Because wet bulb globe temperature accounts for humidity, radiant heat and air movement as well as air temperature, and those are what actually determine heat strain on a working person.

On an apron the radiant component is significant, so WBGT and air temperature can differ substantially at the same moment.

Gill engineering insightThis is the measurement most often approximated from a forecast. The apron is a large dark surface next to aircraft that have just landed, and it does not behave like the nearest reference station.

It measures ferrous wear debris in the oil, reporting fine and coarse separately alongside water presence and oil temperature, so a failing drive is visible before it fails.

It fits as a smart sump-plug replacement or in a bypass circuit, with 0-10 V, 4-20 mA, CANbus or Modbus RTU output.

Because there is no float. Equipment that spends the day accelerating, braking and turning gives a float a reading that depends more on the movement than on the contents, and the float is another component to jam.

On lift, boom, platform and steering mechanisms. Blade sensors measure across a gap to a passive activator, so there is no mechanical contact to wear, and they are sealed to IP67 for temporary immersion (1 m for 30 min).

Generally yes. WearDetect fits as a sump-plug replacement or in a bypass circuit, and level and position sensors are selected against the tank and mechanism arrangement. The engineering team can advise on fittings and mounting.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.