News
Downloads
Careers
Home › Industries and applications › Research and environment
Instrumented research mast in open countryside
Research and Environment

Decades of data.
It starts with the first reading.

Research-grade 3-axis wind measurement, reference weather, optical precipitation and calibration for flux towers, environmental monitoring networks, field campaigns and long-term reference sites.

1985
Building ultrasonic wind sensors in the UK
100 Hz
R3-100 and HS-100 output rate
<1%
Research range wind speed accuracy
150+
Countries where Gill operates

A dataset is an asset, and its weakest season sets its value

Environmental research runs on continuity. A flux record, a reference series or a monitoring network is worth what its least reliable period allows, because a gap or a step change has to be declared every time the data is used.

That puts instrument selection somewhere unusual: the decision is made once, and its consequences are argued over for a decade. A sensor that drifts, ices or changes model mid-series creates work in every paper and every report that follows.

The measurement has to survive the study, not just the deployment.

The measurements behind environmental research

A research site depends on a network of measurements. High-rate three-dimensional wind above and below the canopy, a vertical profile across several heights, reference temperature, humidity and pressure, solar radiation, precipitation, and the power and telemetry that keep it all running unattended.

Different questions need different measurements, rates and locations. The instrumentation has to work as a system, not as a collection of individual sensors.

Where independent verification is required, Labcal provides UKAS-accredited calibration for equipment from multiple manufacturers across six measurement parameters, so a group can keep a mixed instrument estate on one traceable schedule.

The science sets the data rate

Eddy covariance and turbulence work need the vertical wind component resolved at high frequency. A sensor chosen for robustness rather than rate will produce a record that cannot answer the question it was deployed for.

R3-100 and HS-100 output at 100 Hz

Continuity beats peak accuracy

A very accurate instrument that fails for a winter is worth less than a slightly less accurate one that does not. Gaps have to be declared, and they narrow what the dataset can support.

No moving parts to seize or replace

The site is remote and the power is finite

Solar and battery sites trade measurement against endurance. Power draw, not price, is often what decides which instruments make it onto the mast.

Research range draws under 4 W in operation

The method section gets read closely

Peer review, regulators and funders all ask how the measurement was verified. Traceable calibration is what converts an instrument reading into a defensible figure.

UKAS-accredited, ISO/IEC 17025:2017

Research sensing map

Every research question starts at a measurement point

A research site measures across the whole landscape. Three-dimensional wind above and below the canopy. A vertical profile across several heights. Reference conditions, radiation, precipitation and the river the catchment drains to.

Explore 16 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Technical
insight

Why output rate, not accuracy, is usually the deciding specification

Most sensor comparisons start with accuracy. For flux and turbulence work that is the wrong first question. The eddies that carry the flux are short-lived, so the instrument has to sample fast enough to resolve them before its accuracy is relevant at all.

The Research range answers that directly. The R3-50 and HS-50 output at 50 Hz, the R3-100 and HS-100 at 100 Hz, all across 0 to 45 m/s with wind speed accuracy under 1 percent, 0.01 m/s resolution and individual calibration supplied as standard.

Head geometry is the second question. Symmetrical heads suit all-direction work, horizontal heads suit vertical-flow analysis with minimal disturbance from the sensor itself, and the HS models carry a built-in inclinometer to help get the set-up right on a tower.

Rate and geometry are therefore selection decisions, not specification details. They decide whether the instrument can answer the question the study was designed to ask.

Make an enquiry

Find your research application

Six research and environmental monitoring applications where measurement, integration and calibration meet the demands of a dataset that has to last.

Flux tower carrying 3-axis anemometers above woodland
Flux measurement

Eddy Covariance and Flux Towers

Resolve the eddies that carry the flux

Flux measurement stands or falls on sampling rate and on how little the instrument disturbs the flow it is measuring. Above-canopy and sub-canopy positions ask different things of the head geometry, and the tower has to keep running through the seasons that define the record.

Engineering: Research-grade 3-axis anemometry, head geometry selection, traceable calibration.

View Eddy Covariance

Gill MetConnect weather station installed as a reference measurement point
Reference networks

Reference and Long-Term Monitoring

The record everything else is compared against

A reference site is judged on continuity and siting rather than headline accuracy. WMO-compliant separation of sensors by height, third-party instrument integration and a calibration history that survives staff changes all matter more than a specification sheet.

Engineering: Separable weather stations, WMO siting, multi-parameter calibration.

View Reference Monitoring

Technician operating a portable air quality sampler
Air quality

Air Quality and Dispersion

Attribution needs the meteorology beside it

A concentration measurement on its own cannot be traced to a source. Wind speed, direction and turbulence recorded at the same location and the same time are what turn a reading into an attribution, and the analysers usually need to feed the same station.

Engineering: 3-axis turbulence measurement, analogue and Pt100 inputs, systems integration.

View Air Quality and Dispersion

Rainfall striking wet ground
Hydrometeorology

Catchment and Hydrometeorology

Rainfall that keeps measuring when it matters

Catchment studies pair precipitation with river response, and both records have to survive the events they exist to capture. At a remote gauge the maintenance burden of the instrument is part of the measurement quality.

Engineering: Optical precipitation measurement, SDI-12 integration, remote deployment.

View Catchment and Hydrometeorology

A portable met mast with guy lines on a glacier below mountain peaks
Field campaigns

Field Campaigns and Portable Deployments

Come back with a complete record

A campaign has a fixed window and no second chance. Weight, power draw, setup time and configuration in poor conditions decide whether the dataset is complete, which is the only measure of success that counts afterwards.

Engineering: Compact and low-power sensing, portable stations, rapid configuration.

View Field Campaigns

Multirotor uncrewed aircraft in flight carrying airborne instrumentation
Airborne

UAV and Airborne Profiling

Every gram is traded against endurance

Atmospheric profiling from an uncrewed platform puts hard limits on mass, power and ingress protection before accuracy is even discussed, and the ground reference has to be there at launch and recovery.

Engineering: Compact low-power anemometry, portable ground references, integration support.

View UAV Launch Sites

Research and environmental technologies

Products and services engineered for research and long-term environmental monitoring, spanning research-grade anemometry, reference weather measurement, optical precipitation and calibration across Gill.

Meteorological Technology

Gill Research range 3-axis anemometers
Flux and turbulence

Research range

R3 and HS 3-axis ultrasonic anemometers

The highest data rates in the range, with individual calibration supplied as standard. Chosen where the measurement will be published.

Output rate : R3-50 and HS-50 at 50 Hz; R3-100 and HS-100 at 100 Hz
Accuracy : Wind speed accuracy under 1 percent, resolution 0.01 m/s
Power : 9 to 30 V DC, under 4 W in operation, IP65

View the Research range

Gill WindMaster 3-axis ultrasonic anemometers
General 3-axis

WindMaster

3-axis ultrasonic anemometer

Where the work needs the vertical component but not the highest data rate. Symmetrical, asymmetrical, horizontal and right-angled heads.

Output rate : WindMaster Pro 32 Hz; WindMaster 20 Hz with a 32 Hz option
Range : WindMaster Pro 0 to 65 m/s, stainless steel head
Environment : IP65, operating -40 to +70 degrees C

View WindMaster

Gill MetConnect weather stations
Reference stations

MetConnect

Separable weather station with third-party inputs

The station for WMO-compliant siting and for bringing existing instruments into one record.

Inputs : Pt100 to IEC 60751, two analogue inputs, contact closure for rainfall
Outputs : RS232, RS422, RS485, Modbus and SDI-12; ASCII, NMEA 0183, SDI-12 v1.3
Power : 5 to 30 V DC, less than 70 mA at 12 V DC

View MetConnect

Gill MaxiMet compact weather stations
Plots and campaigns

MaxiMet

All-in-one weather station, no moving parts

One unit, one cable, one output string, which is what makes plot-scale replication and short campaigns practical.

Solar : GMX301 measures solar radiation only, 0 to 1600 W per square metre
Wind : 0 to 60 m/s across the range, WindSonic-based
Rainfall : GMX603 carries optical rainfall to 0 to 200 mm/hr, 5 percent or better

View MaxiMet

Precipitation and compact sensing

Gill TruMet PW100 optical rain gauge
Precipitation

TruMet PW100

Infrared optical rain gauge

A solid-state alternative to the tipping bucket, with a pulse output that replicates one so it joins an existing hydrometric record without a step change.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Build : No moving parts, IP66, operating -35 to +70 degrees C
Limits : Liquid precipitation only, measurement range 0 to +70 degrees C

View TruMet PW100

Gill WindUltra compact ultrasonic anemometer
Airborne and mobile

WindUltra

Compact 2-axis wind sensor

Built for platforms where weight, power draw and ingress protection decide whether a sensor can be carried at all.

Build : Compact 2-axis ultrasonic, IP69k
Power : Low-power design for battery and solar platforms
Use : UAV and USV platforms, temporary and harsh-environment installations

View WindUltra

Gill WindSonic ultrasonic anemometers
Profile levels

WindSonic

Lightweight 2-axis ultrasonic anemometer

The economical way to add measurement levels to a profile mast, with a heated variant for cold sites.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Not sure which product fits?Tell us whether it is for a field campaign, a flux tower or a long-term network, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity, all under one roof.

For research and environmental measurement that includes anemometers, Pitot tubes and thermal probes, alongside pressure gauges and transducers, thermometers, temperature and humidity probes and data loggers. Labcal supports equipment from Gill and other manufacturers, which matters on a site where the instruments arrived over twenty years and several projects.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems · Low-flow laboratory to higher-flow industrial

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment · Water used for the accredited capability

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.
Explore Calibration Services

The measurement has to reach the logger that keeps the record

A research measurement is almost never read at the instrument.

It feeds loggers, acquisition systems and monitoring networks, often ones that are already running and cannot be interrupted without breaking the series. That makes the interface part of the specification rather than something to solve after the instrument has been chosen.

Whether the requirement is SDI-12 into a hydrometric logger, RS422 at 100 Hz into an acquisition system, or third-party analysers feeding the same station, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • RS422 & RS232 : High-rate digital acquisition, RS232 via the PCI interface
  • SDI-12 & Modbus : Hydrometric and environmental logger networks
  • Analogue & Pt100 : Third-party analysers and soil probes on the same station
  • MetSet & MetView : Free configuration, display and logging software
Need output rates, head geometry advice or power figures?Data rates, head selection, interface options and calibration certification. Direct from our engineering team.

Request information

Why research groups specify Gill

01

Data rates the science actually needs

The R3-100 and HS-100 output at 100 Hz, the R3-50 and HS-50 at 50 Hz, with wind speed accuracy under 1 percent and 0.01 m/s resolution.

02

Individual calibration as standard

Every Research range instrument is individually calibrated, so the traceability question is answered before the instrument reaches the tower.

03

Head geometry for the flow you have

Symmetrical for all-direction work, horizontal for vertical-flow analysis with minimal disturbance, with a built-in inclinometer on the HS models for tower set-up.

04

Built for unattended service

No moving parts, heated options across the 2-axis range, and a Research range that draws under 4 W in operation on a 9 to 30 V DC supply.

05

Designed to join an existing record

RS422, RS232, SDI-12 v1.3, Modbus and NMEA 0183, with analogue and Pt100 inputs so third-party instruments feed the same station rather than a parallel one.

06

Traceability that survives review

Independent UKAS-accredited calibration across six parameters, for equipment from any manufacturer, so a mixed estate stays on one schedule.

Specifying for a research programme?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Research and environment application notes

3 application pages and 21 numbered application notes for this sector. The pages describe the measurement problem and the instruments that answer it; the numbered notes are the original engineering documents, each with its PDF.

All application notes

Research measurement questions, from data rate to traceability

Measurement and technology

High enough to resolve the turbulent eddies carrying the flux, which for most surfaces means tens of hertz. The R3-50 and HS-50 output at 50 Hz and the R3-100 and HS-100 at 100 Hz.

Gill engineering insightRate first, accuracy second. An instrument that samples too slowly loses flux regardless of how accurate each individual sample is, and the correction for that loss becomes an assumption in the result.

Where accurate vertical-flow analysis matters and the sensor geometry itself would otherwise disturb the flow being measured. The HS-50 and HS-100 use a horizontal head, as does the WindMaster HS.

Gill engineering insightThe HS models also carry a built-in inclinometer, which is more useful than it sounds when you are levelling a head on a tower in wind.

0 to 45 m/s across R3-50, R3-100, HS-50 and HS-100, with 0 to 359 degrees on direction. These are accuracy and data-rate instruments rather than storm-survival sensors.

Among other things, sensors separated by height rather than grouped in one housing, and placement clear of obstructions. MetConnect exists for exactly this: it separates the sensors and accepts third-party analogue, Pt100 and contact-closure inputs.

Specification and integration

The Research range runs from 9 to 30 V DC, drawing less than 150 mA at 24 V DC and under 4 W in operation. MetConnect runs from 5 to 30 V DC at less than 70 mA at 12 V DC.

Gill engineering insightOn a solar and battery site the power budget usually decides the instrument list before anyone discusses specifications. Work it out at design stage, not after the mast is up.

RS422 is native on the Research range. RS232 and analogue outputs are available through the PCI or PCIA interface, which needs to be specified alongside the instrument.

Yes. MetConnect accepts a four-wire Pt100 to IEC 60751, two analogue inputs at 0 to 5 V or 4 to 20 mA, and a contact closure for a tipping-bucket rain input, with 5 V power available on the additional sensor connectors.

Both measure three axes. The Research range goes to 50 or 100 Hz with individual calibration as standard and is built for measurement quality. WindMaster tops out at 32 Hz and covers general 3-axis work, site survey and OEM integration.

Gill engineering insightIf the data is going to be published as flux, that is a Research range job. If the question is turbulence intensity or general 3-axis flow, WindMaster is usually the right level.
Applications and long records

Wind speed, direction and turbulence alongside the concentration measurement, at the same location and time base. Without the meteorology, a concentration cannot be attributed to a source.

Tipping buckets have moving parts, block with debris and under-read in light precipitation. The TruMet PW100 measures optically with no moving parts, 0 to 200 mm/hr at 5 percent accuracy and 0.1 mm resolution.

Gill engineering insightIt outputs one pulse per 0.1 mm, replicating a tipping bucket, so it joins an existing series without a protocol change. Note it measures liquid precipitation only.

Match the output format and the calibration traceability, and where possible run the old and new instruments in parallel for a season so the relationship between them is measured rather than assumed.

Gill engineering insightThis is the single most common regret on long-running sites. A parallel season is cheap; retrofitting a correction to twenty years of data is not.

The 2-axis range has heated variants: the WindObserver models are heated, icing tested to MIL-STD-810F and operate to -55 degrees C with heating, and the WindSonic M is heated aluminium operating to -40 degrees C. The Research range operates from -40 to +60 degrees C, except the HS-100 which is 0 to +50 degrees C.

Gill engineering insightThe HS-100 operating range is the one that catches people out. Check it against the site before specifying it for a cold-climate deployment.
Calibration and engineering

Set by the group, the network protocol and what the data is used to argue. Where results are published or used for regulatory reporting, an annual traceable calibration is common.

Labcal is UKAS-accredited to ISO/IEC 17025:2017 and calibrates air velocity, temperature, humidity, pressure, and gas and liquid flow.

Gill engineering insightBecause Labcal is independent and calibrates any manufacturer, a group can keep instruments bought across twenty years and several projects on one traceable schedule.

Six: gas and air flow, air velocity, liquid flow, pressure, temperature and humidity. Labcal is an independent UKAS-accredited laboratory, Lab 0625, and calibrates equipment from any manufacturer, not only equipment supplied by Gill.

MetSet for configuration and MetView for display and logging are free. Budget configuration time rather than software cost.

Yes. Alongside the standard range, Gill engineers develop embedded and integrated solutions where an off-the-shelf instrument does not fit the platform or the acquisition system.

Question not answered here?Ask our experts directly. You will speak to someone who knows the instruments and where they are used.

Ask our experts

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.