Glasshouses and polytunnels

The control decision
is made on the weather outside

Reference weather measurement outside the structure and non-contact position feedback on the vents and screens inside it, both built to keep working through years of humidity and constant cycling.

IP67
Blade position sensors, IP67 for temporary immersion
0
Moving parts in an ultrasonic anemometer
6
Parameters from one MaxiMet unit
360
Degrees of rotary measurement on Blade360

Two things fail, and both fail slowly

Protected cropping control acts on outside conditions. Vents open against wind and rain, screens move with light and temperature, and heating responds to the external demand, so the outside reference is the input to almost every decision the system makes.

If that reference drifts, nothing alarms. The structure simply runs slightly wrong for a season, and the cost appears as crop quality and energy use rather than as a fault.

The actuator feedback has the same problem in reverse. A vent that reports fully closed while sitting slightly open is an energy leak nobody is looking for, and the position sensor telling that story lives in humidity and cycles thousands of times a year.

Farm sensing map

One holding. Multiple measurement points.

A farm is not one measurement environment.

Wind at the field boundary can be different from the regional forecast. Conditions inside a grain store are different from those outside it. Water levels change with use and rainfall. Machinery develops wear while the rest of the operation continues around it.

Explore the measurement points across a working agricultural holding and see where environmental, level, condition and position sensing can support the operation.

Get expert advice

Need position feedback, BMS integration or reference siting detail?Non-contact position sensing, control integration, output formats and mounting. Direct from our engineering team.

Request information

The reference outside and the feedback inside

The outside reference needs wind, rain, temperature, humidity and light, and it needs them from a position that represents the structure rather than a sheltered corner of the site. Wind matters most because vent strategies are constrained by it and because a wrong reading either risks the structure or wastes the venting.

The instrument is on a roof or a mast, outdoors, for years. Anything with a rotating element eventually fouls with dust, pollen and insects, and an anemometer that has seized reports calm, which reads as ideal venting conditions.

Inside, position feedback closes the loop. Vent, screen and damper positions decide whether the control strategy is actually being executed, and that measurement sits in condensing humidity, continuous cycling and, in some houses, spray.

A contacting position sensor in that environment is a consumable. Non-contact inductive sensing measures across a gap to a passive activator, so there is nothing in contact to wear out.

The input to every control decision

Getting the external measurement right is worth more than tuning the control loops, because a good strategy acting on a poor reference produces poor comfort and poor energy use with no obvious cause.

MaxiMet brings wind, temperature, humidity, pressure, solar radiation and rainfall into one unit on one cable, and ultrasonic wind measurement means there is no rotating element to foul with pollen, dust or insects.

One reference, no moving parts

View MaxiMet

Confirm the vent actually closed

Control systems generally assume an actuator went where it was commanded. Over a season of thousands of cycles that assumption develops a gap, and the gap is an energy cost that never appears as an alarm.

Blade position sensors measure across a gap to a passive activator with no mechanical contact, sealed to IP67 for temporary immersion (1 m for 30 min). Blade25 measures 25 mm and Blade60 measures 60 mm of linear travel, and Blade360 provides a full 360 degrees of rotary measurement.

Commanded and confirmed are different

Explore position sensors

Energy and quality are both reviewed

Protected cropping is energy intensive and margin sensitive, and both get reviewed against the season rather than the day. A record of external conditions and actual actuator positions is what makes that review useful instead of anecdotal.

It is also what makes a control change arguable. Changing a venting strategy on the basis of a measured season is a different conversation from changing it on the basis of how the house felt in July.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across temperature, humidity, pressure, air velocity and flow.

What a protected cropping site measures

The outside reference the control system acts on, and the position feedback that confirms it was executed.

Outside reference

Gill MaxiMet compact weather stations
Reference station

MaxiMet

All-in-one weather station, no moving parts

Wind, temperature, humidity, pressure, solar radiation and rainfall from one unit on one cable, sited to represent the structure.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Gill WindSonic ultrasonic anemometers
Vent strategy

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight ultrasonic wind measurement where the vent and screen strategy is constrained by wind speed and direction.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Gill TruMet PW100 optical rain gauge
Rainfall

TruMet PW100

Infrared optical rain gauge

Optical rainfall measurement with nothing to block with pollen, dust or insects, feeding rain-close strategies.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Output : One pulse per 0.1 mm, replicating a tipping bucket
Build : No moving mechanism to block or seize

View TruMet PW100

Inside the structure

Gill Blade non-contact position sensors
Actuators

Blade position sensors

Non-contact inductive position sensing

Non-contact position feedback on vents, screens and dampers, sealed to IP67 for condensing humidity and continuous cycling.

Linear : Blade25 measures 25 mm, Blade60 measures 60 mm, both configurable
Rotary : Blade360 measures a full 360 degrees and is sealed to IP67 for temporary immersion
Sealing : IP67 across the range, sealed for temporary immersion (1 m for 30 min)

Explore position sensors

Gill capacitive liquid level sensors
Tanks and dosing

Level sensing

Capacitive liquid level sensors

Continuous level in nutrient, water and dosing tanks with no float, including a FEP-coated variant for aggressive solutions.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Gill MetConnect weather stations
Multi-point

MetConnect

Separable sensors for WMO-compliant siting

Separable sensors where the site keeps reference measurement at defined heights or across several structures.

Siting : Separable sensors mounted at the heights the standard expects
Inputs : Accepts third-party, analogue and Pt100 inputs
Models : MetConnect One and MetConnect THP

View MetConnect

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where protected cropping measurement does the work

Glasshouses

Vent and screen control

External reference driving venting, screening and heating, with feedback confirming execution.

Polytunnels

Simpler structures

Wind and rain measurement where the structure itself is the thing being protected.

Propagation

Tight tolerances

Environments where small control errors show up quickly in the crop.

Energy management

Heating strategy

External demand measurement behind the largest single cost in the operation.

Multi-site nurseries

Consistent control

One measurement architecture across structures so that settings mean the same thing everywhere.

Irrigation and dosing

Tank and supply

Level measurement across nutrient and water systems feeding the same control platform.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For a nursery carrying anemometers, thermal probes, pressure instruments, thermometers, temperature and humidity probes and data loggers, one accredited laboratory keeps the whole site on a single traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting reference and feedback into the control system

Protected cropping control is done by a climate computer or a building management system, and both the external reference and the actuator feedback have to arrive in it rather than alongside it.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so growers, control suppliers and structure manufacturers can bring measurement into existing control architecture.

Whether the requirement is Modbus into a climate computer, analogue into an existing input, a serial string into a display, or a configurable sensor embedded into an OEM build, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • Modbus RTU : Climate computers and BMS
  • 4-20 mA & 0-10 V : Existing analogue inputs
  • RS232 & RS485 : Serial links and local displays
  • BladeCom : Travel, switch points and output limits set before fitting

What the specification looks like in practice

01

The reference decides everything downstream

A good control strategy acting on a drifting external measurement produces poor results with no obvious cause.

02

Nothing to foul with pollen or dust

Ultrasonic wind measurement has no rotating element, which is what fails first on a nursery roof.

03

Commanded is not the same as achieved

Non-contact position feedback confirms that a vent or screen actually reached the position the system believes it did.

04

Built for condensing humidity

Blade sensors are sealed to IP67 for temporary immersion (1 m for 30 min), with no mechanical contact between sensor and activator.

05

One unit for the whole reference

MaxiMet returns wind, temperature, humidity, pressure, solar and rainfall on one cable.

06

Into the climate computer you run

Modbus, analogue and serial outputs reach existing control platforms.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about glasshouses and polytunnels

Reference measurement and actuator feedback

Because vents, screens and heating all respond to external conditions, so the reference is the input to nearly every decision the control system takes. If it drifts, the structure runs slightly wrong for a season without alarming.

Gill engineering insightThis is the measurement most worth calibrating, because an error in it is multiplied across every control decision rather than appearing as a single fault.

Confirmation that the actuator reached the commanded position. Control systems generally assume it did, and over thousands of cycles that assumption develops a gap that shows up as energy cost rather than as an alarm.

Blade sensors measure across a gap to a passive activator with no mechanical contact, and are sealed to IP67 for temporary immersion (1 m for 30 min), which suits condensing humidity and continuous cycling.

Blade25 measures 25 mm and Blade60 measures 60 mm of linear travel, both configurable, and Blade360 provides a full 360 degrees of rotary measurement for pivot and screen drives.

Generally yes. The sensors provide Modbus RTU, analogue and serial outputs, and the engineering team can advise on the interface a particular climate computer or BMS expects.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.