News
Downloads
Careers
Home › Products › Weather stations › MetConnect

FLEXIBLE PROFESSIONAL WEATHER STATION

Your weather system. Your configuration.

Professional environmental measurement when one fixed configuration isn’t enough

MetConnect One weather station

Integrated or remote wind

One integrated, THP remote

Temperature, RH and pressure

Separate by height, per WMO

316 stainless steel hub box

Fits a 30 to 58 mm pole or mast

Third-party sensor inputs

Pt100, analogue, contact closure

  • Integrated or remote windMetConnect One carries a WindSonic, THP takes a remote Gill anemometer
  • Sensors at different heightsSeparate the measurements in line with WMO siting recommendations
  • Bring your own sensorsPt100, two analogue inputs and a contact closure rain input
  • 316 stainless steel hub boxFits a 30 to 58 mm pole or mast

The measurement problem

When the measurement problem doesn't fit in one box

A compact integrated weather station is wonderfully convenient when its configuration matches the job. But what if it doesn't? A national weather network may need a particular anemometer and additional sensors. A coastal monitoring station may need measurements positioned independently. An environmental monitoring system may need to add sensors later.

MetConnect is designed for those situations. Its modular architecture combines integrated weather sensors with connector inputs for additional user-selected sensors, allowing measurements to be brought together into a coordinated system.

That flexibility matters because the cheapest sensor is not necessarily the cheapest system. If the architecture forces compromises in sensor placement, additional interfaces or future expansion, the saving tends to disappear rather quickly.

Integrated or remote wind

An integrated WindSonic on One, a remote Gill anemometer on THP.

WMO-compliant siting

Sensors sit at different heights, where each one belongs.

Third-party inputs

Pt100, analogue and contact closure, with 5 V power on the connectors.

One coordinated output

Time-synchronised data from every sensor, through one output.

Choose your MetConnect

One question decides the MetConnect

Both are separable stations built for WMO-compliant siting, where sensors sit at different heights. The difference is whether the wind sensor comes with it.

Built to orderMetConnect One

MetConnect One

Integrated windT/H/PThird-party inputs

When an integrated, unheated wind sensor is what the site needs, alongside temperature, humidity and pressure.

Integrated WindSonic, unheatedIP66 and IP67 hub · 3.0 kg
Built to orderMetConnect THP

MetConnect THP

T/H/PRemote wind inputThird-party inputsCold-capable

When wind needs to live somewhere else, or the site is cold enough to need a heated anemometer, fitted remotely.

No integrated windIP66 and IP67 hub · 3.0 kg
Additional inputs on both models

Both accept a contact closure rain input, a 4-wire Pt100 temperature probe to IEC 60751 and two analogue inputs, 0-5 V or 4-20 mA, with 5 V power available on the sensor connectors. The contact closure input is how both connect the TruMet PW100 optical rain gauge.

Not sure which MetConnect you need? Our team will tell you in one reply.Make an enquiry

MetConnect vs other Gill weather stations

Start with one question: integrated or configurable

MetConnect makes the measurement system more configurable. MaxiMet makes the weather station smaller and simpler. Neither is universally better. The choice depends on what you measure, where the sensors need to sit and whether the architecture is likely to change.

MaxiMet GMX500
Look at MaxiMet

When one compact instrument does the job

  • A defined combination of measurements in one housing
  • One unit, one cable, one output string
  • Less to install and commission than a separable station
MaxiMet GMX260MaxiMet GMX560
Look at MaxiMet Marine

When the platform moves

  • IP68 as well as IP66
  • 6-axis compass with heading, pitch and roll
  • GMX260 for wind, GMX560 for wind plus T/H/P

Choosing between them

Where does the wind sensor need to live?

That one question separates the two configurations. Both accept additional sensors, so the measurement set is not what decides between them. Every figure is from the released datasheet.

SpecificationWind with the stationMetConnect OneWind somewhere elseMetConnect THP
Choose it whenThe wind sensor can sit with the rest of the measurementWind needs a different height or position, or the site is cold
WindIntegrated WindSonic, 0 to 60 m/s, unheatedRemote Gill anemometer, connected by M12
Wind accuracy±2% RMS and ±3° at 12 m/sFrom the connected anemometer
Temperature-35 °C to +70 °C, 0.2 °C accuracy-35 °C to +70 °C, 0.2 °C accuracy
Relative humidity0 to 100% RH, 1.5% RH at 25 °C0 to 100% RH, 1.5% RH at 25 °C
Pressure300 to 1100 hPa, ±0.5 hPa300 to 1100 hPa, ±0.5 hPa
Cold sitesNoWith a heated WindObserver or WindSonic M
Additional inputsRain, Pt100, 2 analogueRain, Pt100, 2 analogue
Hub box316 stainless steel, 3.0 kg316 stainless steel, 3.0 kg
DatasheetDatasheetDatasheet
SpecificationCore weatherGMX500Adds rainfallGMX600Most accurate rainfallGMX603Sensors mounted apartMetConnect One
Choose it whenWind, temperature, humidity and pressure are enoughYou need rainfall as well as core weatherRainfall accuracy matters mostSensors need different heights, or you want to add your own
ConstructionOne compact housingOne compact housingOne compact housingSeparable sensors on a stainless hub
Wind0 to 60 m/s0 to 60 m/s0 to 60 m/s0 to 60 m/s, integrated WindSonic
RainfallNoOptical, 0 to 300 mm/hrOptical, 0 to 200 mm/hr, 5% or betterVia the contact closure rain input
Third-party inputsNoNoNoPt100, 2 analogue, rain
Sensors at different heightsNoNoNoYes
IP ratingIP66IP66IP66IP66, hub box IP66 and IP67
Weight0.7 kg0.8 kg1.1 kg3.0 kg hub box
DatasheetDatasheetDatasheetDatasheetDatasheet

Why modular

Because not every measurement belongs in the same place

There is a difference between putting several sensors in one enclosure and designing a measurement system properly. Wind measurement may need a clear exposure above the installation. Temperature and humidity may need to be positioned differently. In some applications, the sensor you need simply isn't part of a standard integrated weather station.

MetConnect allows additional user-selected sensors to be connected through dedicated M12 inputs, so the measurement architecture can reflect the physical requirements of the application. The point of modularity is not more things to configure. It is fewer compromises.

2analogue inputs0-5 V or 4-20 mA
1Pt100 input4-wire, to IEC 60751
1rain inputcontact closure, for TruMet PW100
1data outputtime-synchronised across every sensor
Weather station with a louvred radiation shield beside a solar farm
Solar site station

Integration

One measurement system. One coordinated data stream.

Modular systems can create their own problems. More sensors can mean more cables, more interfaces and more power requirements, and separate data streams make time alignment harder than it needs to be.

MetConnect combines data from its integrated sensors with the sensors connected to it and provides time-synchronised measurements through a single data output. That reduces the power and communications complexity that can otherwise come with building a multi-sensor weather system.

  • RS232, RS422, RS485, SDI-12 and Modbus
  • ASCII, Modbus RTU and ASCII, NMEA0183, SDI-12 v1.3
  • 1 measurement per 1, 2 or 4 seconds, or polled
WindSonic on a monitoring mast beside a reservoir
WindSonic on a mast

Choosing the wind sensor

The weather station doesn't dictate the anemometer

On MetConnect THP the wind sensor is not a fixed part of the package. The station takes a remote Gill anemometer, so engineers can select the instrument that makes sense for the application.

WindSonic is the straightforward choice when dependable 2-axis wind measurement and low maintenance are the priority. WindObserver makes more sense where the application calls for a higher-specification sensor, including demanding marine, aviation or hazardous-area environments. For cold sites, pair THP with a heated WindObserver or WindSonic M.

Low maintenance

Ultrasonic wind measurement means no mechanical wind-sensing components to wear or replace, with a stainless steel hub and IP66 and IP67-rated connections.

View specifications →

Software and configuration

MetSet, free configuration software, and MetView, free display and logging software, take the station from installation to data review.

Download MetSet and MetView →

Cold sites

MetConnect One's integrated WindSonic is unheated. For cold climates, specify MetConnect THP with a heated remote anemometer.

Explore MetConnect THP →

Technical specification

The architecture is flexible. The specification is precise.

SpecificationMetConnect OneMetConnect THP
WindIntegrated WindSonic, 0 to 60 m/sRemote Gill anemometer, M12 input
Wind accuracy±2% RMS, ±3° at 12 m/sFrom the connected anemometer
Temperature, humidity, pressureIntegratedIntegrated
Additional inputsContact closure rain, Pt100, 2 analogueContact closure rain, Pt100, 2 analogue
OutputsRS232, RS422, RS485, SDI-12, ModbusRS232, RS422, RS485, SDI-12, Modbus
Environmental protectionIP66, hub box IP66 and IP67IP66, hub box IP66 and IP67
Construction316 stainless steel hub box316 stainless steel hub box
Datasheet1733-0001 Iss 21733-0002 Iss 1

Exact electrical, dimensional, environmental and sensor compatibility specifications should be taken from the relevant Gill datasheet for the configuration being specified.

See it work

MetConnect, measuring what you cannot improve blind

Three short films on separable sensing, and the sites where putting sensors at different heights is the whole point.

You can’t improve what you don’t measure

54 seconds · The case for measuring

Every chemical plant monitors its processes

57 seconds · Process industry

Winning conditions in Macau

53 seconds · Motorsport

Prefer to watch them together? Watch them all on the Gill Group channel

Accessories

MetConnect accessories

Cables, connectors, mounting, set-up kit and replacement sensors for MetConnect. Pick a model to see only the parts that fit it.

Show parts for

Showing all 10 parts

Cables

  • Power and comms cable, 2 m, M12 fittedPart no. 1733-PK-011 2 m
  • Power and comms cable, 10 m, M12 fittedPart no. 1733-PK-013 10 m
  • Power and comms cable, 20 m, M12 fittedPart no. 1733-PK-014 20 m
  • Cable, 4 pair, cut to lengthPart no. 1733-PK-010 Per metre

Connectors

  • M12 connector, 8 way, field wireablePart no. 1733-PK-002

Mounting

  • Bracket mounting kitPart no. 1733-PK-022 For re-mounting

Set-up and configuration

  • M12 to USB adaptorPart no. 1733-PK-030
  • M12 to USB adaptor cablePart no. 1733-PK-031

Spares

  • Replacement pressure sensorPart no. 1733-PK-040
  • Replacement temperature and humidity sensorPart no. 1733-PK-041

Order accessories with your sensor or on their own. Quote the part number when you get in touch. See the accessories datasheet

Questions

Frequently asked questions

What is a MetConnect weather station?

MetConnect is Gill Instruments' range of multi-parameter professional weather stations with inputs for additional user-selected sensors. The platform is designed for applications where the required measurement set or sensor arrangement does not fit a fixed, all-in-one weather-station configuration.

Can I use a different wind sensor with MetConnect?

Yes. MetConnect is designed to accommodate a remote, user-selected wind sensor in appropriate configurations. Gill identifies WindSonic and WindObserver as wind-sensor options within its MetConnect architecture.

Can MetConnect connect additional sensors?

Yes. MetConnect provides connector inputs for additional user-selected sensors. MetConnect One and THP each provide three additional M12 sensor connections, while THP also provides a dedicated M12 connection for a remote wind sensor.

Can MetConnect combine data from multiple sensors?

Yes. The platform is designed to combine data from its integrated sensors with connected additional sensors, providing time-synchronised data through the weather station's output. This can reduce the power and communications complexity of a multi-sensor system.

Does MetConnect use ultrasonic wind measurement?

Yes. MetConnect uses ultrasonic technology for wind measurement in compatible configurations. Because there are no moving mechanical wind-sensing components, the system avoids the mechanical wear associated with conventional cup-and-vane anemometers.

Is MetConnect low maintenance?

MetConnect is designed for reliable, low-maintenance operation. Ultrasonic wind measurement eliminates mechanical wind-sensing components, while robust construction and high-IP-rated connectors support use in challenging environments.

Can MetConnect be used for marine applications?

Yes. MetConnect is suitable for applications including ports, harbours, coastal monitoring and ocean buoys. For more demanding moving marine platforms requiring IP68 protection and integrated heading, pitch and roll information, MaxiMet Marine may be the more appropriate architecture.

Is MetConnect suitable for professional weather networks?

Yes. Gill states that the MetConnect concept has been selected by national weather administrations and global multinationals, reflecting its suitability for professional weather-monitoring applications where configurable measurement architectures are required.

What environmental protection does MetConnect have?

The MetConnect hub box is rated IP66 and IP67, and the temperature and humidity sensor and the wind sensor are rated IP66. The hub box and bracket are 316 stainless steel, the sensor housings are UV-stabilised polycarbonate, and the connectors are high-IP-rated for challenging environments. The exact protection specification should be checked against the relevant configuration and datasheet.

Have an application to discuss?

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

Enquiring about MetConnect

  • Our team replies. Not an account manager, and not a queue.
  • We aim to respond in one working day. Monday to Friday.
  • No obligation. Plenty of these end with us saying it is not our product.