Facade access and cradles

The cradle is on the facade.
The wind limit should be too.

Ultrasonic wind measurement mounted at the facade the crew is working on, with non-contact position feedback on the equipment and traceable calibration behind the decision to stop.

0
Moving parts to seize on a facade
IP67
Blade position sensors, IP67 for temporary immersion
0.5 kg
WindSonic mounting weight
6
UKAS-accredited calibration parameters

The reading and the crew are on different sides of the building

Building maintenance units and cradles stop at a defined wind speed, and the reading that stops them usually comes from an anemometer on the plant room roof, which is the most exposed and least representative point on the structure.

A crew on a leeward facade may be stopped by conditions they are not experiencing, which costs access time on a programme that is already constrained. A crew on the windward side may not be stopped by conditions they are.

Whichever way the error runs, the sensor itself is in the worst possible place for maintenance. A facade or roof-edge instrument is reached by rope access or by the very equipment it controls, so anything that needs servicing effectively does not get serviced.

Built environment sensing map

One building. Seventeen measurement points.

A building measures from the roof to the basement, and from the plant room to the pavement outside.

Wind above the parapet, at the facade and at the kerb. Conditions for ventilation and plant. Rainfall and level for drainage. Position on everything that moves. Measurement for the machinery that keeps the building operating.

Explore the measurement points across a typical built environment and see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need facade mounting, position feedback or calibration certification?Facade mounting, non-contact position sensing, output formats and traceable calibration. Direct from our engineering team.

Request information

Measured on the elevation being worked

Wind at a facade differs from wind at a roof anemometer by a large factor, and the sign of the difference depends on direction. Around a tall building, corner acceleration and downwash create conditions on one elevation that bear no relation to the reference reading.

Putting the measurement on the facade removes that entirely. The limit is then applied against the conditions the crew is actually in, which is both safer and less wasteful of access time.

The instrument has to last. Facade positions are reached by rope access or by the cradle itself, so a sensor with a rotating element becomes a job that is deferred and then forgotten, and a seized anemometer reports calm.

Position feedback on the equipment is the other half. Knowing where a cradle, davit or restraint mechanism actually is matters to the control system and to the people relying on it.

Stop on what the crew is in

A facade-mounted measurement describes the elevation being worked, which is the condition the limit was written for. A roof reference describes the most exposed point on the building.

WindSonic measures 0 to 60 or 0 to 75 m/s at 0.5 kg, light enough to mount on a facade bracket or the cradle itself without a structural case.

The elevation being worked

View WindSonic

Nothing to service at height

Everything mounted on a facade is expensive to reach and therefore rarely reached. The specification decision that matters most is how little the instrument asks for once it is up there.

Ultrasonic measurement has no rotating element to ice, foul or seize, and Blade position sensors measure across a gap to a passive activator with no mechanical contact, sealed to IP67 for temporary immersion (1 m for 30 min).

Fitted once, left alone

Explore position sensors

A stoppage and an incident are both examined

Access equipment operates under a documented safe system of work, and both a stoppage and an incident are reviewed against it. The wind reading is the central fact in either case.

A reading with no calibration behind it is an assertion. An instrument on a traceable interval supports the decision to continue as well as the decision to stop, and the first is the one more often questioned.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer, which suits a building with instruments fitted by different contractors.

What facade access measures

Wind at the elevation being worked, position feedback on the equipment, and the calibration that makes the stop decision defensible.

Wind at height

Gill WindSonic ultrasonic anemometers
Facade mounted

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight ultrasonic measurement at 0.5 kg, mounted on a facade bracket or the cradle itself.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Gill WindObserver ultrasonic anemometers
Roof reference

WindObserver

Heated 316 stainless open-head 2-axis anemometer

Heated 316 stainless measuring to 0 to 90 m/s for the building reference position that has to survive every winter.

Range : WindObserver 90 measures 0 to 90 m/s; 75 measures 0 to 75 m/s
Build : 316 stainless steel, IP66, heated, icing tested to MIL-STD-810F
Direction : 0 to 360 degrees with no dead band

View WindObserver

Gill WindUltra compact ultrasonic anemometer
Equipment mounted

WindUltra

Compact 2-axis ultrasonic anemometer

A compact 2-axis anemometer sealed to IP69k for mounting on the unit itself.

Build : Compact and lightweight, rated IP66, IP68 and IP69K
Use : UAV, USV, portable and mobile installations
Power : Low-power operation for battery and solar deployments

View WindUltra

Equipment and control

Gill Blade non-contact position sensors
Position feedback

Blade position sensors

Non-contact inductive position sensing

Non-contact position sensing on cradle, davit and restraint mechanisms, sealed to IP67 for temporary immersion (1 m for 30 min).

Linear : Blade25 measures 25 mm, Blade60 measures 60 mm, both configurable
Rotary : Blade360 measures a full 360 degrees and is sealed to IP67 for temporary immersion
Sealing : IP67 across the range, sealed for temporary immersion (1 m for 30 min)

Explore position sensors

Gill capacitive liquid level sensors
Hydraulics

Level sensing

Capacitive liquid level sensors

Continuous level in hydraulic reservoirs on building maintenance units, with no float to jam.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Gill MaxiMet compact weather stations
Building conditions

MaxiMet

All-in-one weather station, no moving parts

Wind, temperature, humidity, pressure, solar radiation and rainfall where the building keeps a fuller record.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where facade access measurement does the work

Building maintenance units

Roof-mounted machines

Wind measurement at the working position rather than at the machine.

Suspended cradles

Temporary access

Measurement that travels with the cradle down the elevation.

Rope access

Working at height

Conditions at the facade supporting the decision to descend or to stop.

Tall buildings

Corner effects

Elevations where downwash and corner acceleration make a roof reference meaningless.

Facade replacement

Long programmes

Access programmes where unnecessary stoppages compound across months.

Estate compliance

Documented systems

Measurement supporting a safe system of work that will be examined.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For access equipment and building instruments carrying anemometers, thermal probes, pressure instruments and data loggers, one accredited laboratory keeps instruments fitted by different contractors on a single traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting the limit to the equipment and the crew

A stop decision is executed by the access equipment control system and taken by a person, so the measurement has to reach a controller and a display.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so access equipment manufacturers, facade contractors and building operators can bring measurement into control systems.

Whether the requirement is analogue into an equipment controller, Modbus into a building system, a serial string into a display, or a configurable sensor embedded into an OEM build, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • 4-20 mA & 0-10 V : Equipment controllers and interlocks
  • Modbus RTU : Building and estate systems
  • RS232 & RS485 : Displays and local readout
  • BladeCom : Travel, switch points and output limits set before fitting

What the specification looks like in practice

01

Measured on the working elevation

Wind at a facade differs from a roof reference by a large factor, and the sign depends on direction.

02

Access time not wasted

Stopping a leeward crew on windward conditions costs programme time that compounds across a long access job.

03

No servicing at height

No rotating element to ice, foul or seize on an instrument reached by rope access.

04

Light enough to mount anywhere

WindSonic measures 0 to 75 m/s at 0.5 kg, mountable on a facade bracket or the cradle.

05

Position without a wear item

Blade sensors measure across a gap to a passive activator, sealed to IP67 for temporary immersion (1 m for 30 min).

06

Defensible either way

Independent UKAS-accredited calibration across six parameters, so the decision to continue is as supportable as the decision to stop.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about facade access and cradles

Wind limits and access equipment

Because it is the most exposed and least representative point on the building. A crew on a leeward elevation may be stopped by conditions they are not in, and a crew on the windward side may not be stopped by conditions they are.

Gill engineering insightAround tall buildings the difference is not a small correction. Corner acceleration and downwash create facade conditions that bear little relation to a roof reading.

That is set by the equipment manufacturer and the safe system of work rather than by the instrument. What the instrument decides is whether the limit is applied against a reading that represents the working position.

Ultrasonic sensors have no rotating element to ice, foul or seize, which matters most in a position reached by rope access or by the equipment it controls.

On cradle, davit and restraint mechanisms. Blade sensors measure across a gap to a passive activator with no mechanical contact, sealed to IP67 for temporary immersion (1 m for 30 min).

The sensors provide analogue, Modbus and serial outputs that can feed an equipment controller. The interlock function itself is specified by the equipment manufacturer against the installation requirements.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.