Home › Industries and applications › Research and environment › Catchment and hydrometeorology
Rainfall striking wet ground
Catchment and hydrometeorology

The gauge has to survive
the event it exists to record

Optical precipitation measurement and capacitive level sensing for catchment studies, with low-power SDI-12 integration for remote sites where the maintenance burden is part of the measurement quality.

0
Moving parts in an optical rain gauge
0.1 mm
TruMet PW100 rainfall resolution
200 mm/hr
Measurement range, so intensity is not clipped
0
Moving parts in a capacitive level sensor

The record fails on the day it matters most

A catchment study pairs precipitation with river response, and the pairing only has value across the events that define the catchment. A record that is complete for eleven months and missing the storm is not most of a dataset.

That is precisely when instruments fail. A tipping bucket cannot keep up with high intensity rainfall and under-reports the peak, or it blocks with debris and reports nothing. A level sensor with a float finds the moving water that the study exists to measure.

Remote gauges compound it. A site chosen for hydrological reasons is usually a site chosen against access, so the visit that would have found the fault does not happen until after the event has passed.

Research sensing map

Every research question starts at a measurement point

A research site measures across the whole landscape. Three-dimensional wind above and below the canopy. A vertical profile across several heights. Reference conditions, radiation, precipitation and the river the catchment drains to.

Explore 16 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need SDI-12 integration, mounting or power budget detail?Optical precipitation, level sensing, low-power configuration and protocol documentation. Direct from our engineering team.

Request information

Intensity, accumulation and level, all through the same storm

Rainfall intensity drives the hydrograph. Accumulation over an hour tells you the volume and hides the shape, and the shape is what produces the peak flow a catchment study is trying to explain.

A tipping mechanism measures by counting discrete tips, which caps the intensity it can resolve and introduces error that grows with rate. Optical measurement counts the precipitation passing through a beam, so high intensity is measured rather than approximated.

Water level is the other half. Capacitive sensing gives continuous level with no float, in a channel carrying debris, silt and whatever the catchment has picked up upstream.

Both then have to report from a site with no mains power, on a power budget that assumes nobody is visiting until spring. That makes low-power integration a measurement decision, not an installation detail.

Optical measurement does not block or miss the peak

A tipping bucket depends on a mechanism, and mechanisms fill with leaves, insects and silt. Once blocked it reports a dry catchment during the event, which is the failure that costs a season of work.

TruMet PW100 uses infrared optical measurement rather than a tipping mechanism, measuring 0 to 200 mm/hr with 5 percent accuracy and 0.1 mm resolution. It outputs one pulse per 0.1 mm, replicating a tipping bucket, so it drops into a logger that already expects one.

The peak measured, not clipped

View TruMet PW100

Everything is designed against the site visit

A gauge sited for hydrological reasons is usually awkward to reach, so every service visit costs a day and often a vehicle. The specification decision that matters is how rarely the instrument needs one.

Capacitive level sensing has no float and fully sealed solid-state electronics, with LevelSlick FEP coated for particulate and viscous liquids. Combined with low-power SDI-12 output into a logger, a site can run through a season unattended.

Specify for the visit you will not make

Explore level sensors

A catchment dataset outlives the project

Flood studies, consent applications and model calibration all reach back into catchment records collected years earlier by someone else, and they ask which instrument, sited where, calibrated when.

That makes traceability part of the dataset rather than part of the paperwork. An instrument on a traceable interval keeps a record usable long after the project that funded it has closed.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer, which matters across a catchment instrumented over several funding rounds.

What a catchment site carries

Precipitation measurement that survives the storm, level sensing that survives the channel, and the meteorology behind evaporation and snowmelt.

Precipitation and level

Gill TruMet PW100 optical rain gauge
Intensity

TruMet PW100

Infrared optical rain gauge

Optical rainfall measurement to 0 to 200 mm/hr, so the intensity that drives the hydrograph is measured rather than clipped by a mechanism.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Output : One pulse per 0.1 mm, replicating a tipping bucket
Build : No moving mechanism to block or seize

View TruMet PW100

Gill capacitive liquid level sensors
Water level

Level sensing

Capacitive liquid level sensors

Continuous level with no float, including a FEP-coated variant for water carrying particulate and silt.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Gill MaxiMet compact weather stations
Site record

MaxiMet

All-in-one weather station, no moving parts

One unit and one cable for the supporting meteorology, including solar radiation and wind for evaporation estimates.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Meteorology and profiles

Gill MetConnect weather stations
Profiles

MetConnect

Separable sensors for WMO-compliant siting

Separable sensors where temperature and humidity need to sit at defined heights alongside the hydrological measurement.

Siting : Separable sensors mounted at the heights the standard expects
Inputs : Accepts third-party, analogue and Pt100 inputs
Models : MetConnect One and MetConnect THP

View MetConnect

Gill WindSonic ultrasonic anemometers
Wind

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight ultrasonic wind measurement for evaporation and snowmelt work, with heated options for upland sites.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Gill WindObserver ultrasonic anemometers
Upland

WindObserver

Heated 316 stainless open-head 2-axis anemometer

Heated 316 stainless for exposed upland catchments where icing would otherwise create the gap.

Range : WindObserver 90 measures 0 to 90 m/s; 75 measures 0 to 75 m/s
Build : 316 stainless steel, IP66, heated, icing tested to MIL-STD-810F
Direction : 0 to 360 degrees with no dead band

View WindObserver

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where catchment measurement does the work

Flood studies

Rainfall and response

Pairing intensity with river level through the events that define the catchment.

Upland catchments

Exposed gauges

Sites where snow, ice and access all argue against a mechanism.

Urban drainage

Fast response

Small catchments where the hydrograph is sharp and hourly accumulation explains nothing.

Model calibration

Long series

Records used to calibrate and then to re-calibrate hydrological models years apart.

Consent monitoring

Discharge and abstraction

Level and rainfall records supporting regulatory positions.

Research catchments

Instrumented basins

Sites carrying instruments from several projects on one power and telemetry budget.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For a catchment carrying rain gauges, level sensors, thermal probes, pressure instruments, temperature and humidity probes and data loggers, one accredited laboratory keeps instruments installed over several funding rounds on a single traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting data off a site nobody is visiting

A catchment gauge reports from a location with no mains power, often no mobile coverage and no routine visit, and it has to keep doing so through the season it exists to measure.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so agencies, consultants and research groups can bring measurement into loggers, telemetry and catchment databases.

Whether the requirement is SDI-12 into a low-power logger, a pulse output replacing a tipping bucket, or analogue into an existing channel, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • SDI-12 : Low-power loggers on remote gauges
  • Pulse output : One pulse per 0.1 mm, replacing a tipping bucket
  • 4-20 mA & 0-10 V : Existing analogue channels
  • Modbus RTU : Telemetry and catchment systems

What the specification looks like in practice

01

The peak is measured, not clipped

Optical measurement to 0 to 200 mm/hr resolves the intensity that drives the hydrograph, where a tipping mechanism caps it.

02

Nothing to block

No tipping mechanism means no leaves, insects or silt stopping the gauge during the event.

03

Drops into the logger you have

One pulse per 0.1 mm replicates a tipping bucket, so an existing installation does not need rewriting.

04

Level without a float

Capacitive sensing has no moving component in water carrying debris and silt, with a FEP-coated option for the worst of it.

05

Built for a season alone

Low-power SDI-12 operation and sealed construction, for sites where the next visit is in the spring.

06

Traceable years later

Independent UKAS-accredited calibration across six parameters, for equipment from any manufacturer.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about catchment and hydrometeorology

Precipitation, level and remote sites

Because it measures by counting discrete tips, which caps the intensity it can resolve and introduces error that grows with rate. It also blocks with leaves, insects and silt, and a blocked gauge reports a dry catchment during the storm.

TruMet PW100 uses infrared optical sensing measuring 0 to 200 mm/hr with 5 percent accuracy and 0.1 mm resolution.

Gill engineering insightFor catchment work the intensity matters more than the total, because the shape of the hyetograph is what produces the peak flow being explained.

Usually. TruMet PW100 outputs one pulse per 0.1 mm, replicating a tipping bucket, so an existing logger configuration generally continues to work.

Because there is no float to foul in water carrying debris and silt. LevelSlick uses a FEP-coated construction for particulate, viscous and corrosive liquids, and LevelPro is stainless at IP66 and IP68.

SDI-12 output suits low-power loggers, which is the usual arrangement on a battery and solar site. The power budget should be reviewed as part of specifying the station.

If the work includes evaporation, snowmelt or gauge undercatch, yes. Ultrasonic wind measurement avoids the rotating element that ices on upland sites, with heated options where that matters.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.