News
Downloads
Careers
Home › Industries and applications › Industrial process › Gas engines and combined heat and power
A gas engine with its manifolds and ignition leads in a plant room
Gas engines and combined heat and power

The engine only earns
while it turns

Ignition modules and closed-loop air and fuel ratio control for gas engines, CHP and gensets, where ignition energy, timing and a drifting gas composition decide availability and efficiency.

3
Ignition modules: GS8, GS12 and GT6
AF120
Closed-loop air and fuel ratio controller
CAN
Integration into engine and plant control
2
Debris classes, fine and coarse, on WearDetect

A stopped engine earns nothing and still costs

A CHP or genset installation is financed on running hours. The capital is spent whether it runs or not, and the return arrives only while it is generating, which makes availability the whole business case rather than a performance metric.

Most of what stops a gas engine is not dramatic. It is misfire that was tolerated, ignition energy that fell away with the plugs, or a mixture that drifted with the gas and took efficiency down with it before anyone looked.

Gas composition is the complication that engines on natural gas do not share. Landfill, digester and biogas all vary through the day and across a season, and an engine tuned against a fixed assumption is only correct occasionally.

Process sensing map

Every process decision starts at a measurement point

A plant measures across the whole site. Level in vessels and bulk storage. Position on valves and actuators. Oil condition in rotating machinery, ignition and mixture on the engines, and wind at the stack, the flare and the fence line.

Explore 16 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need ignition configuration, control integration or engine detail?Ignition energy and timing, closed-loop control, CAN integration and drawings. Direct from our engineering team.

Request information

Ignition and mixture decide what the engine returns

Ignition energy has to be sufficient for the mixture actually present rather than for the mixture assumed at commissioning. A lean mixture needs more energy to light, and an ignition system that was adequate on a rich gas becomes marginal when the composition moves.

Timing carries the same problem. Ignition advance that suits one gas quality is not optimal for another, and the engine reports the difference as reduced output or as knock rather than as a diagnostic.

Closed-loop air and fuel ratio control is what makes a variable gas manageable. Measuring and correcting continuously keeps the engine at the ratio it should be running at while the composition moves underneath it.

Beneath both, the mechanical condition of the engine is doing its own drift. Ferrous debris accumulates in the lubricant through the whole degradation process, well before vibration or performance shows anything.

Energy and timing for the gas you actually have

The GS8, GS12 and GT6 ignition modules provide controlled ignition energy and timing for gas engines, on installations running anything from pipeline natural gas to landfill and digester gas.

Controlled ignition matters most where the gas is variable, because that is where a fixed assumption stops being true first. Spark duration and energy are part of the specification rather than a consequence of the coil that was fitted.

Ignition specified, not inherited

View gas engine controls

Closed loop against a moving composition

Open-loop mixture control assumes the gas is what it was at commissioning. On landfill, digester and biogas installations that assumption fails daily, and the cost is efficiency that nobody attributes to anything.

The AF120 provides closed-loop air and fuel ratio control, correcting continuously so the engine runs at the intended ratio while the composition moves. It integrates over CAN into engine and plant control.

Correct the ratio, not the assumption

View gas engine controls

Availability is contracted

CHP installations run under availability guarantees, energy performance contracts and maintenance agreements, all of which are settled from recorded running hours and recorded faults.

That makes engine data commercial rather than technical. A condition and control record that shows what the engine was doing, and when it was corrected, is what supports a position when availability is challenged.

Where the site also carries anemometers, pressure instruments and probes, Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer.

What a gas engine installation carries

Ignition and mixture control for the engine itself, condition monitoring for the drivetrain beneath it, and the site measurement around it.

Engine control

Gill gas engine ignition modules and air fuel ratio controller
Ignition and ratio

Gas engine controls

Ignition modules and air fuel ratio control

GS8, GS12 and GT6 ignition modules with the AF120 closed-loop air and fuel ratio controller, integrating over CAN.

Ignition : GS8, GS12 and GT6 ignition modules
Ratio control : AF120 closed-loop air and fuel ratio controller
Integration : CAN communication into engine and plant control

View gas engine controls

Gill WearDetect oil debris sensors
Condition

WearDetect

Oil debris sensor

Ferrous debris in engine and gearbox oil, reported fine and coarse separately alongside water presence and oil temperature.

Measures : Fine and coarse ferrous debris, water presence, oil temperature
Outputs : 0-10 V, 4-20 mA, CANbus or Modbus RTU
Fitting : Smart sump-plug replacement or bypass circuit

View WearDetect

Gill capacitive liquid level sensors
Fluids

Level sensing

Capacitive liquid level sensors

Oil, coolant and condensate level with no float, with a FEP-coated variant for the liquids a digester site produces.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Plant and site

Gill Blade non-contact position sensors
Actuators

Blade position sensors

Non-contact inductive position sensing

Non-contact position feedback on valve, damper and actuator mechanisms around the engine and the heat network.

Linear : Blade25 measures 25 mm, Blade60 measures 60 mm, both configurable
Rotary : Blade360 measures a full 360 degrees and is sealed to IP67 for temporary immersion
Sealing : IP67 across the range, sealed for temporary immersion (1 m for 30 min)

Explore position sensors

Gill MaxiMet compact weather stations
Site conditions

MaxiMet

All-in-one weather station, no moving parts

Outside temperature and conditions, which is what a heat network is sized against and judged on.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Gill WindObserver ultrasonic anemometers
Classified areas

WindObserver

Heated 316 stainless open-head 2-axis anemometer

Certified wind measurement where the installation includes classified areas around gas handling.

Range : WindObserver 90 measures 0 to 90 m/s; 75 measures 0 to 75 m/s
Build : 316 stainless steel, IP66, heated, icing tested to MIL-STD-810F
Direction : 0 to 360 degrees with no dead band

View WindObserver

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where gas engine control does the work

Landfill gas

Variable composition

Engines running a gas that changes through the day, where closed-loop control is the difference between rated and actual output.

Anaerobic digestion

Biogas installations

Sites where the feedstock decides the gas and the gas decides the engine tune.

CHP schemes

Heat and power

Installations judged on annual efficiency and contracted on availability.

District energy

Plant rooms

Engines in basements and plant rooms where failure is discovered late and access is poor.

Standby generation

Availability on demand

Sets that have to start and carry load on the day they are called, having run rarely.

Engine builders

OEM integration

Ignition and control specified into the build rather than added to it.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

Where the installation also carries anemometers, Pitot tubes, thermal probes, pressure instruments, thermometers, temperature and humidity probes and data loggers, a single accredited laboratory keeps the whole site on one traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting control and condition into the plant system

An engine control decision is taken in milliseconds and reviewed in a monthly report, so the same installation has to serve the engine controller and the plant management system.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so engine builders, operators and plant contractors can bring ignition, mixture and condition data into existing control architecture.

Whether the requirement is CAN into an engine controller, Modbus into plant control, or analogue into an existing channel, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • CAN : Engine controllers and OEM integration
  • Modbus RTU : Plant control and SCADA
  • 4-20 mA & 0-10 V : Existing analogue channels
  • RS232 & RS485 : Serial links and local displays

What the specification looks like in practice

01

Ignition energy as a specification

GS8, GS12 and GT6 provide controlled ignition energy and timing rather than whatever the fitted coil happens to deliver.

02

Closed loop against a moving gas

The AF120 corrects the air and fuel ratio continuously, which is what a variable composition requires.

03

Built for the gases that vary

Landfill, digester and biogas installations are where an open-loop assumption fails first and costs most.

04

Wear seen before the outage

WearDetect reports fine and coarse ferrous debris separately, so a failing component is visible while it is still a component.

05

Level without a float

Capacitive sensing covers oil, coolant and condensate with no moving component in the fluid.

06

Into the controller you already run

CAN, Modbus, analogue and serial outputs, so the measurement reaches the system that already exists.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about gas engines and combined heat and power

Ignition, mixture and condition

Because ignition energy and air fuel ratio both depend on it. Landfill, digester and biogas vary through the day and across a season, so an engine tuned against a fixed assumption is only correct some of the time.

The AF120 provides closed-loop air and fuel ratio control, correcting continuously as the composition moves.

Gill engineering insightThe cost of an open-loop assumption is rarely a fault. It is efficiency quietly below rated, which nobody attributes to anything in particular.

GS8, GS12 and GT6 cover different engine configurations and cylinder counts. The selection depends on the engine, the gas and the control requirement, and the engineering team can advise against the specific installation.

It keeps the engine at the intended air and fuel ratio while the gas composition moves, rather than at a ratio that was correct at commissioning. That shows up as efficiency and as fewer mixture-related faults.

WearDetect monitors ferrous debris in the oil, reporting fine and coarse separately alongside water presence and oil temperature. On an installation contracted on availability, seeing wear before the outage is the point.

The gas engine controls integrate over CAN, and the condition and level sensing provides CAN, Modbus RTU, analogue and serial outputs. The engineering team can advise on the interface a particular controller expects.

Yes. Gill supports OEM integration, and the engineering team can advise on sensor selection, mounting, output formats, communication protocols and installation requirements.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.