News
Downloads
Careers
Home › Industries and applications › Government and emergency › Public estate and community resilience
City skyline at dusk with connected infrastructure
Public estate and community resilience

The alert costs money.
The reading behind it should be yours.

Reference weather measurement and WBGT heat stress monitoring across the public estate, so rest centres, warm spaces and health alerts respond to conditions measured locally rather than regionally.

WBGT
How heat stress is assessed, not air temperature
6
Parameters from one MaxiMet unit
0
Moving parts to service on a roof
6
UKAS-accredited calibration parameters

Regional alerts, local buildings

Cold weather and heat health alerts are issued regionally and acted on locally. A council opens warm spaces, staffs rest centres and changes how buildings are run, and all of that costs money against a threshold that was crossed somewhere in the region.

The difference between the regional figure and the conditions at a particular building can be substantial, particularly in summer. Urban heat means a city centre and the surrounding countryside are not experiencing the same day.

Heat is also the part most often assessed as air temperature, when the index that working and welfare limits are actually written against is wet bulb globe temperature, which accounts for humidity, radiant heat and air movement.

Public sector sensing map

Every public decision starts at a measurement point

Three views of the work public bodies do with measurement: observe and forecast, manage and regulate, warn and respond. From rainfall and rivers to bridges, flood infrastructure and the incident itself.

Choose a view, then explore 25 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need building integration, WBGT configuration or siting detail?Reference stations, heat stress measurement, output formats and BMS integration. Direct from our engineering team.

Request information

Local measurement behind a regional trigger

A regional alert is the right instrument for a regional decision. Deciding which buildings to open, when to change a service and how to staff it is a local decision, and it benefits from a local measurement.

Urban heat is the clearest case. Dense built-up areas hold heat overnight in a way that open countryside does not, so the overnight minimum, which is the figure that matters most for vulnerable people, is different in the two places.

WBGT is the index to measure rather than air temperature, because it combines temperature, humidity, radiant heat and air movement into the single figure that heat strain guidance uses.

The rest of the estate benefits from the same station. Building management, grounds operations, flood response and event decisions all use the same conditions record, which is what makes one installation worth its cost.

WBGT rather than air temperature

Air temperature understates heat strain because it ignores humidity, radiant heat and air movement, and all three vary substantially across an urban estate.

MaxiMet provides WBGT measurement alongside wind, temperature, humidity, pressure, solar radiation and rainfall, so the heat assessment and the general conditions record come from the same unit.

The index the guidance actually uses

View heat stress measurement

One station, several responsibilities

A civic building weather station is difficult to justify for one purpose and easy to justify for six. Heat and cold response, building management, grounds maintenance, event decisions and flood awareness all draw on the same record.

MetConnect separates the sensors by height where a reference-quality record is wanted, and accepts third-party, analogue and Pt100 inputs so instruments already installed in the building can join the same station.

One installation, many users

View MetConnect

Public spending is scrutinised

Opening rest centres and warm spaces costs money, and the decisions are reviewed. A local conditions record supports both the decision to open and the decision not to, which is the harder one to defend.

The same record supports duty of care positions for outdoor staff, where heat stress limits are written against WBGT and applying them needs a measurement rather than a forecast.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer, which suits an estate instrumented across several departments and budgets.

What a public estate measures

Heat stress and the general conditions record from one unit, with reference-quality measurement where the estate keeps a formal record.

Conditions and heat

Gill MaxiMet compact weather stations
Heat and conditions

MaxiMet

All-in-one weather station, no moving parts

WBGT alongside wind, temperature, humidity, pressure, solar radiation and rainfall, from one unit on one cable.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Gill MetConnect weather stations
Reference

MetConnect

Separable sensors for WMO-compliant siting

Separable sensors at defined heights, with third-party and Pt100 inputs bringing existing building instruments into the same record.

Siting : Separable sensors mounted at the heights the standard expects
Inputs : Accepts third-party, analogue and Pt100 inputs
Models : MetConnect One and MetConnect THP

View MetConnect

Gill TruMet PW100 optical rain gauge
Rainfall

TruMet PW100

Infrared optical rain gauge

Optical rainfall measurement with no tipping mechanism to block on a roof nobody visits.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Output : One pulse per 0.1 mm, replicating a tipping bucket
Build : No moving mechanism to block or seize

View TruMet PW100

Buildings and grounds

Gill WindSonic ultrasonic anemometers
Building wind

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight ultrasonic measurement for roof and facade positions feeding building and grounds decisions.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Gill WindMaster 3-axis ultrasonic anemometers
Microclimate

WindMaster

3-axis ultrasonic anemometer

Three-axis measurement where wind comfort or ventilation performance is being assessed rather than monitored.

Output : WindMaster and WindMaster RA provide 20 Hz with options up to 32 Hz
Pro : WindMaster Pro measures 0 to 65 m/s at 32 Hz, 14-bit, stainless head with PRT
Use : Turbulence intensity, flow inclination, vertical component

View WindMaster

Gill capacitive liquid level sensors
Drainage and tanks

Level sensing

Capacitive liquid level sensors

Continuous level in attenuation tanks, water storage and plant, with no float to jam.

LevelPro : Stainless steel, IP66 and IP68, 0-10 V or 4-20 mA, RS232 for configuration
LevelSlick : FEP coated for particulate, viscous and corrosive liquids
LevelLite : Lightweight aluminium, IP68, voltage or current output

Explore level sensors

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where public estate measurement does the work

Warm spaces

Cold weather response

Local measurement behind the decision to open and to staff civic buildings.

Heat health

Vulnerable populations

WBGT measured where people are, including the overnight minimum in built-up areas.

Outdoor workforce

Duty of care

Heat stress limits applied on measurement rather than on a regional forecast.

Schools and leisure

Building management

Conditions feeding ventilation, heating and outdoor activity decisions.

Parks and grounds

Operations

Wind and rainfall behind tree work, event and maintenance decisions.

Community resilience

Planning and review

A conditions record supporting both the response and the review of it.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For a public estate carrying anemometers, thermal probes, pressure instruments, thermometers, temperature and humidity probes and data loggers, often bought by different departments, one accredited laboratory keeps everything on a single traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting conditions into the systems the estate runs

A public estate runs building management systems, asset platforms and reporting tools that already exist, and a conditions measurement is only useful if it reaches them.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so local authorities, estates teams and systems suppliers can bring measurement into existing platforms.

Whether the requirement is Modbus into a building management system, a serial string into a reporting platform, SDI-12 into a logger, or analogue into an existing channel, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • Modbus RTU : Building management and estate systems
  • SDI-12 : Loggers and telemetry
  • 4-20 mA & 0-10 V : Existing analogue channels
  • RS232 & RS485 : Serial links and displays

What the specification looks like in practice

01

Heat stress, not air temperature

Heat guidance is written against wet bulb globe temperature, which accounts for humidity, radiant heat and air movement.

02

Local rather than regional

Urban heat means a city centre and the surrounding countryside are not experiencing the same day, particularly overnight.

03

One station, several departments

Heat and cold response, building management, grounds, events and flood awareness all use the same record.

04

Existing instruments carried in

Third-party, analogue and Pt100 inputs bring building sensors into the same station.

05

Nothing to service on a roof

Ultrasonic wind measurement and optical rainfall remove the mechanisms that need clearing.

06

Defensible when spending is reviewed

Independent UKAS-accredited calibration across six parameters, for equipment from any manufacturer.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about public estate and community resilience

Heat, cold and civic buildings

Because the response is local. Deciding which buildings to open and how to staff them is a local decision, and conditions at a particular building can differ substantially from the regional figure.

Urban heat is the clearest case, because dense built-up areas hold heat overnight in a way open countryside does not.

Gill engineering insightThe overnight minimum is the figure that matters most for vulnerable people, and it is the one where the urban and rural difference is largest.

Because wet bulb globe temperature combines temperature, humidity, radiant heat and air movement into the index that heat strain guidance and working limits are written against.

That is usually what makes it worth installing. Heat and cold response, building management, grounds operations, event decisions and flood awareness can all draw on the same conditions record.

MetConnect accepts third-party, analogue and Pt100 inputs, so instruments already installed in a building can join the same station rather than a separate system.

Generally yes. The sensors provide Modbus RTU, analogue and serial outputs, and the engineering team can advise on the interface a particular BMS expects.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.