Pedestrian wind comfort

The study was done
years before the building existed

Three-axis turbulence measurement and compact street-level sensing to test a wind microclimate study against the real building, at the places people actually stand.

3
Axes, so gusts are resolved not averaged
20 Hz
WindMaster output rate for turbulence
0.5 kg
GMX200 compact station weight
6
UKAS-accredited calibration parameters

A model of a building that had not been built yet

Pedestrian wind comfort is assessed in a wind tunnel or a computational model at planning stage, years before the development exists and before the buildings around it were finished either.

The assessment becomes a planning condition, and sometimes a mitigation scheme of screens, canopies and planting. What almost never happens is a measurement afterwards to see whether the prediction and the mitigation were right.

When complaints arrive they are about specific places: a corner that is unusable, an entrance that cannot be held open, a terrace that was designed to be occupied. Those are gust and turbulence problems at street level, and a mean wind speed from a rooftop cannot describe them.

Built environment sensing map

One building. Seventeen measurement points.

A building measures from the roof to the basement, and from the plant room to the pavement outside.

Wind above the parapet, at the facade and at the kerb. Conditions for ventilation and plant. Rainfall and level for drainage. Position on everything that moves. Measurement for the machinery that keeps the building operating.

Explore the measurement points across a typical built environment and see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

Need street-level mounting, turbulence measurement or study comparison?Three-axis sensing, compact stations, mounting and traceable calibration. Direct from our engineering team.

Request information

Comfort criteria are gust criteria

Wind comfort criteria are written in terms of exceedance: how often a threshold speed is passed at a location, and whether that frequency suits sitting, standing, strolling or walking. They are about the peaks rather than the average.

That makes turbulence the measurement rather than mean wind speed. A location can have a modest average and be unusable because of the gusts a nearby corner is shedding into it.

Position matters more than in almost any other application. Wind comfort varies over metres around a building corner, so the measurement has to be at the place people complained about rather than nearby.

Three-axis measurement resolves the structure that buildings generate, including the downwash and corner acceleration that make a study and a reality diverge. A scalar reading averages exactly the information the criteria depend on.

Resolve the gusts the criteria are about

Comfort criteria are exceedance criteria, so the measurement has to capture short-duration peaks rather than a smoothed mean. Averaging is the one thing that destroys the quantity being assessed.

WindMaster provides three-axis measurement at 20 Hz with options up to 32 Hz, resolving the vertical component and the turbulence structure that buildings shed, which is what a verification study needs.

Peaks measured, not smoothed

View WindMaster

Measured where people stand

Wind comfort changes over metres. A measurement at a rooftop reference is a different quantity from the conditions at a doorway, and the doorway is what the complaint is about.

Compact sensing makes street-level positions practical. GMX200 measures wind at 0.5 kg and WindUltra is a small 2-axis anemometer sealed to IP69k, both mountable on street furniture, facades and temporary masts without a structural case.

At the corner, not on the roof

View WindUltra

A planning condition is a long-term obligation

Wind comfort conditions attach to a development and persist. If a location does not perform, the question is what the study predicted, what was built, and what the conditions actually are.

A measured record is the only one of those three that can be established after the fact, and it is what makes a mitigation scheme arguable rather than speculative.

Labcal is an independent UKAS-accredited laboratory operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer, which matters when a measurement supports a planning position.

What a wind comfort study measures

Three-axis measurement for the turbulence the criteria are written about, and compact sensing for the street-level positions that matter.

Turbulence and reference

Gill WindMaster 3-axis ultrasonic anemometers
Verification

WindMaster

3-axis ultrasonic anemometer

Three-axis measurement at 20 Hz with options up to 32 Hz, resolving the gust structure a comfort criterion is written about.

Output : WindMaster and WindMaster RA provide 20 Hz with options up to 32 Hz
Pro : WindMaster Pro measures 0 to 65 m/s at 32 Hz, 14-bit, stainless head with PRT
Use : Turbulence intensity, flow inclination, vertical component

View WindMaster

Gill Research range 3-axis ultrasonic anemometers
Detailed study

Research range

50 Hz and 100 Hz 3-axis anemometers

50 Hz and 100 Hz three-axis measurement at 14-bit resolution where the flow structure itself is the subject.

Rate : R3-50 and HS-50 provide 50 Hz; R3-100 and HS-100 provide 100 Hz
Resolution : 14-bit digital measurement resolution
Head : Standard head on R3, horizontal head on HS

View Research range

Gill WindObserver ultrasonic anemometers
Rooftop reference

WindObserver

Heated 316 stainless open-head 2-axis anemometer

Heated 316 stainless for the undisturbed reference the street-level measurements are compared against.

Range : WindObserver 90 measures 0 to 90 m/s; 75 measures 0 to 75 m/s
Build : 316 stainless steel, IP66, heated, icing tested to MIL-STD-810F
Direction : 0 to 360 degrees with no dead band

View WindObserver

Street level

Gill WindUltra compact ultrasonic anemometer
Compact

WindUltra

Compact 2-axis ultrasonic anemometer

A small 2-axis anemometer sealed to IP69k, mountable on street furniture, facades and temporary masts.

Build : Compact and lightweight, rated IP66, IP68 and IP69K
Use : UAV, USV, portable and mobile installations
Power : Low-power operation for battery and solar deployments

View WindUltra

Gill MaxiMet compact weather stations
Site station

MaxiMet

All-in-one weather station, no moving parts

Wind, temperature, humidity, pressure, solar radiation and rainfall from one unit where the study needs the wider record.

Full station : GMX551 carries wind, temperature, humidity, pressure, solar and rainfall
Compact : GMX200 is 0.5 kg and measures wind only
Rainfall : GMX600 and GMX603 carry optical rainfall measurement

View MaxiMet

Gill WindSonic ultrasonic anemometers
Survey positions

WindSonic

Lightweight 2-axis ultrasonic anemometer

Lightweight ultrasonic measurement at 0.5 kg for multiple survey points around a development.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where wind comfort measurement does the work

Tall buildings

Downwash and corners

Verifying predicted conditions at the base of buildings that generate their own microclimate.

Public realm

Squares and terraces

Spaces designed to be occupied, assessed against whether they actually are.

Entrances

Doors and lobbies

Locations where wind decides whether a door is usable and a lobby works.

Mitigation schemes

Screens and planting

Measuring before and after, so mitigation is judged rather than assumed.

Planning conditions

Post-completion

Verification where a condition attached to consent requires it.

Masterplans

Phased development

Measurement as a site builds out, when each phase changes the last one.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

For a verification study carrying anemometers, thermal probes, pressure instruments, temperature and humidity probes and data loggers, one accredited laboratory keeps the whole measurement set on a single traceable schedule.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.

Explore Calibration Services

Getting survey data into the assessment

A wind comfort study produces synchronised measurement from several positions, and reconciling time bases afterwards is what usually costs the analysis budget.

Gill supports environmental monitoring, industrial sensing, embedded electronics and systems integration, so consultants, developers and local authorities can bring survey measurement into acquisition and analysis chains.

Whether the requirement is a digital output into an acquisition system, Modbus into a site network, SDI-12 into a logger, or analogue into an existing channel, Gill engineers can support integration from specification through commissioning.

Outputs and options

  • Modbus RTU : Site systems and SCADA
  • SDI-12 & serial : Loggers and remote telemetry
  • 4-20 mA & 0-10 V : Existing analogue channels
  • Traceable calibration : So the record holds up on review

What the specification looks like in practice

01

Gusts rather than means

Comfort criteria are exceedance criteria, and averaging destroys the quantity being assessed.

02

Three axes around buildings

Downwash and corner acceleration have a vertical component that a 2-axis instrument cannot resolve.

03

Street-level measurement

Wind comfort changes over metres, so a rooftop reference describes a different quantity from a doorway.

04

Small enough for street furniture

WindUltra is compact and sealed to IP69k, and GMX200 measures wind at 0.5 kg.

05

Nothing to service in public

No rotating element to foul or seize on equipment mounted where the public can reach it.

06

Traceable for a planning position

Independent UKAS-accredited calibration across six parameters, for equipment from any manufacturer.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about pedestrian wind comfort

Microclimate and verification

Because comfort criteria are exceedance criteria. They describe how often a threshold is passed at a location, so the peaks are the quantity and the average hides them.

A location can have a modest mean and be unusable because of gusts shed from a nearby corner.

Gill engineering insightThis is why verification studies that use a single scalar anemometer rarely settle an argument. They measure something adjacent to the criterion rather than the criterion itself.

Because downwash and corner acceleration have a substantial vertical component, and a 2-axis instrument cannot resolve it. WindMaster provides three-axis measurement at 20 Hz with options up to 32 Hz.

At the locations in question, which is usually where a complaint originated or where the study predicted a problem. Wind comfort varies over metres, so nearby is not the same as there.

It can measure what the conditions actually are, which is the missing term in the comparison. The study, the as-built geometry and the measurement together are what make a verification meaningful.

Long enough to capture the directions and conditions the criteria are assessed against, which is a study design question rather than an instrument one. The engineering team can advise on the measurement arrangement.

Yes. Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017, calibrating equipment from any manufacturer across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.