Calibration: humidity

Humidity calibration from 10 to 90 %rh

UKAS-accredited calibration for hygrometers, humidity transmitters, combined temperature and humidity probes and dew point sensors, carried out in environmental chambers in Lymington by Labcal, the Gill Group's calibration laboratory.

What is humidity calibration?

Humidity calibration places an instrument in an environmental chamber held at a known, stable relative humidity and compares its reading with a traceable reference. The certificate records the humidity error and uncertainty at each point, which is what cleanroom, storage and GMP monitoring records depend on.

Unlike pressure or temperature, relative humidity cannot be applied directly to a sensor, so the whole instrument has to sit in a controlled atmosphere. Labcal's chambers also calibrate the temperature probes built into humidity instruments, and dew point sensors are accredited from -15 °C to 40 °C.

Digital humidity and temperature display
Humidity display

Relative humidity, dew point and the temperature beside them

The humidity range depends on chamber temperature, and the uncertainty depends on probe length, so tell us the instrument and the conditions it works in.

Humidity calibration accredited ranges and best measurement capability
Instrument or quantityRangeExpanded uncertainty (k=2)
Relative humidity, at 15 to 40 °C10 to 90 %rh1.5 %rh
Relative humidity, at 10 to 15 °C15 to 90 %rh1.5 %rh
Temperature probes built into humidity meters-5 to 10 °C0.22 °C
Temperature probes built into humidity meters10 to 40 °C0.15 °C
Dew point-15 to 0 °C0.35 °C
Dew point0 to 20 °C0.18 °C
Dew point20 to 40 °C0.21 °C

Ranges and best measurement capability from the UKAS schedule of accreditation for laboratory 0625, issue 055, 18 August 2026. Q[a, b] means the two terms are combined in quadrature. The uncertainty on your certificate depends on the instrument under test.

Check your instrument with us

The instruments that guard storage, cleanrooms and processes

01

Hygrometers

Handheld and fixed hygrometers used for spot checks and environmental monitoring.

02

Humidity transmitters

Transmitters feeding building management, cleanroom and process control systems.

03

Combined temperature and humidity probes

Probes calibrated for relative humidity and for the temperature sensor built into them.

04

Dew point sensors

Dew point instruments, accredited from -15 °C to 40 °C dew point.

05

Environmental data loggers

Loggers used to record storage, transport and laboratory conditions.

06

Humidity controllers

Relative humidity controllers and indicators, calibrated with their sensor where possible.

Typical makes include Fluke, HygroPalm, Michell Instruments, Rotronic, RS, RS PRO, Testo, TSI and Vaisala.

From your bench to a certificate and back

01

Tell us what needs calibrating

Use the form on this page with the instrument, the quantity and the points you need. If you are moving from another laboratory, your current certificate is enough for a like-for-like quote, usually within 24 hours.

02

Send it to Lymington

Instruments come to the Labcal laboratory at Ampress Park, Lymington. Calibration is laboratory based rather than on site. Courier collection can be arranged for regular and high-volume customers.

03

Calibration against traceable references

Turnaround averages 8 working days from the day the instrument arrives, with a 3-day fast track available by arrangement. Where an instrument can be adjusted, it is recorded as found, adjusted and recorded again as left.

04

Certificate and return

A UKAS certificate states the measured values, the expanded uncertainty at k=2 and the traceability to national standards, with as-found and as-left results where adjustment was made.

Tell us what needs calibrating

The instrument, how many and the points you need are enough to start. If you are switching laboratory, mention it and we will ask for your current certificate so the quote matches it like for like.

This field is for validation purposes and should be left unchanged.
We send the quote here.
Sending more than one? List them all here.
What do you need?(Required)
Switching from another laboratory? We will ask for your current certificate so the quote matches it like for like.
Please enter a number greater than or equal to 1.
Calibration is priced per unit.
Month and year if you know it.

UKAS accredited. Labcal, laboratory 0625, ISO/IEC 17025:2017.

We aim to respond in one working day. Turnaround averages 8 working days from arrival, with a 3-day fast track by arrangement.

Switching laboratory? Send your current certificate for a like-for-like quote.

Frequently asked questions

Labcal's UKAS accreditation covers relative humidity from 10 %rh to 90 %rh at chamber temperatures of 15 °C to 40 °C, and from 15 %rh to 90 %rh at 10 °C to 15 °C, with an expanded uncertainty of 1.5 %rh. Dew point is accredited from -15 °C to 40 °C.

Humidity is calibrated in an environmental chamber because relative humidity cannot be applied to a sensor the way a pressure or a temperature can. The instrument has to be exposed to a stable, known atmosphere, and the reference instrument measures the same air, so both readings can be compared directly.

Yes. Labcal's UKAS schedule includes temperature probes built into humidity meters, from -5 °C to 40 °C, calibrated in the same environmental chamber. This is useful for combined probes where both readings feed environmental monitoring or GMP records, because both readings are then covered by the same certificate.

The calibration interval for a humidity instrument should be set by your quality system, based on how critical the measurement is, the accuracy needed and the sensor's drift at previous calibrations. Annual calibration is commonly adopted in pharmaceutical manufacturing and in cleanroom and HVAC monitoring.

Probe length can affect the achievable uncertainty, which is why Labcal's UKAS schedule states that the humidity and built-in temperature uncertainties depend on probe length. Tell us the probe dimensions when you ask for a quote so the laboratory can confirm what it can achieve.

Talk to an engineer

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.