News
Downloads
Careers
Eddy covariance flux tower instrumented above a woodland canopy
Eddy covariance

Years of data depend on
fractions of a second

Research-grade 3-axis anemometry at 50 and 100 Hz for eddy covariance, flux towers and the long-running datasets built on them.

100 Hz
R3-100 and HS-100 output rate
<1%
Research range wind speed accuracy
<4 W
Research range power in operation
1985
Building ultrasonic wind sensors in the UK

The eddies carrying the flux are short-lived, and so is your chance to measure them

Eddy covariance works by correlating the vertical wind component with a scalar concentration at high frequency. The transport happens in turbulent structures that pass the sensor in fractions of a second.

An instrument that samples too slowly does not measure a slightly noisier flux. It misses part of the transport entirely, and the loss has to be estimated afterwards with a spectral correction that becomes an assumption in the published result.

That reverses the usual specification order. Output rate is the first question, head geometry is the second, and accuracy only becomes the deciding factor once both are satisfied.

Need output rates, head geometry advice or interface options?Data rates, head selection, PCI and PCIA interfaces and calibration certification. Direct from our engineering team.

Request information

What the flux calculation asks of the anemometer

Three things, in order. Enough sampling rate to resolve the transporting eddies. A head geometry that does not disturb the vertical flow it is measuring. And a calibration you can cite.

The Research range answers all three directly. The R3-50 and HS-50 output at 50 Hz, the R3-100 and HS-100 at 100 Hz, all across 0 to 45 m/s with wind speed accuracy under 1 percent, 0.01 m/s resolution, and individual calibration supplied as standard.

Head geometry is the part most often decided by habit. Symmetrical heads suit all-direction work where the footprint moves with the wind rose. Horizontal heads suit accurate vertical-flow analysis with minimal geometric disturbance, and the HS models carry a built-in inclinometer, which is more useful than it sounds when you are levelling a head on a tower in wind.

The rest of the tower matters too. A radiation measurement and a soil term for the energy balance, a profile for the gradient, and a power budget that lets all of it run unattended.

Flux tower sensing map

Where a flux measurement actually comes from

A flux tower measures above and below the canopy, at more than one height, alongside the radiation and soil terms that let the energy balance be closed.

Explore 9 measurement points to see what is being measured, where the measurement happens and which sensing technology fits the application.

Get expert advice

100 Hz, and accuracy under 1 percent

The R3-100 and HS-100 output at 100 Hz, the R3-50 and HS-50 at 50 Hz. All four measure 0 to 45 m/s across 0 to 359 degrees with wind speed accuracy under 1 percent and 0.01 m/s resolution.

Individual calibration is supplied as standard rather than as an option, so the traceability question is answered before the instrument reaches the tower.

Individually calibrated as standard

View the Research range

Choose the head to the flow, not to the catalogue

Symmetrical heads suit work where the footprint moves with wind direction and every sector matters equally. Horizontal heads minimise the disturbance the sensor itself causes to vertical flow, which is the term eddy covariance depends on.

The HS-50 and HS-100 use a horizontal head and carry a built-in inclinometer to help get the set-up right on a tower. The WindMaster HS offers the same geometry at 32 Hz where the highest rate is not required.

Horizontal heads for vertical-flow work

Compare 3-axis anemometers

A flux record is judged on its worst season, not its best instrument

Flux sites run for years, and the value of the dataset is set by its gaps. A winter lost to a failed instrument is a caveat on every analysis that uses the record afterwards.

That makes two unglamorous properties decisive. Power draw, because most towers run on solar and battery and the budget decides what can be installed at all. And instrument continuity, because changing model mid-series introduces a step change that has to be declared in every paper.

The Research range runs from 9 to 30 V DC drawing under 4 W in operation. Where an instrument does have to be replaced, matching the output format and the calibration traceability, and running old and new in parallel for a season, is what keeps the series intact.

More than the sonic anemometer

Research-grade anemometry alongside the reference measurement, radiation and soil inputs a flux tower needs.

Research and 3-axis anemometry

Gill Research range 3-axis anemometers
Flux measurement

Research range

R3 and HS 3-axis ultrasonic anemometers

The highest data rates in the range, with individual calibration as standard. Chosen where the measurement will be published.

Output rate : R3-50 and HS-50 at 50 Hz; R3-100 and HS-100 at 100 Hz
Accuracy : Wind speed accuracy under 1 percent, resolution 0.01 m/s
Power : 9 to 30 V DC, under 4 W in operation, IP65

View the Research range

Gill WindMaster 3-axis ultrasonic anemometers
Profile and general 3-axis

WindMaster

3-axis ultrasonic anemometer

Where the work needs the vertical component but not the highest rate, including additional profile levels on the same tower.

Output rate : WindMaster Pro 32 Hz; WindMaster 20 Hz with a 32 Hz option
Range : WindMaster Pro 0 to 65 m/s, stainless steel head
Heads : Symmetrical, asymmetrical, horizontal and right-angled

View WindMaster

Gill WindSonic ultrasonic anemometers
Additional levels

WindSonic

Lightweight 2-axis ultrasonic anemometer

The economical way to add horizontal measurement levels to a profile mast.

Range : WindSonic 60 measures 0 to 60 m/s; WindSonic 75 to 0 to 75 m/s
Accuracy : Full-range accuracy published for WindSonic 60 and 75
Options : WindSonic M is heated aluminium, operating to -40 degrees C

View WindSonic

Reference and site measurement

Gill MetConnect weather stations
Reference and soil

MetConnect

Separable weather station with third-party inputs

The station that brings soil probes, compatible radiometers and existing instruments into one record.

Inputs : Four-wire Pt100 to IEC 60751, two analogue inputs, contact closure for rainfall
Outputs : RS232, RS422, RS485, Modbus and SDI-12; ASCII, NMEA 0183, SDI-12 v1.3
Power : 5 to 30 V DC, less than 70 mA at 12 V DC

View MetConnect

Gill MaxiMet compact weather stations
Radiation and reference

MaxiMet

All-in-one weather station, no moving parts

The GMX301 is the solar-only node for the radiation term; the GMX551 covers the full reference set in one housing.

Solar : GMX301 measures solar radiation only, 0 to 1600 W per square metre
Full station : GMX551 carries wind, T, H, P, solar and rainfall
Rainfall : GMX603 carries optical rainfall to 0 to 200 mm/hr, 5 percent or better

View MaxiMet

Gill TruMet PW100 optical rain gauge
Precipitation

TruMet PW100

Infrared optical rain gauge

Rainfall with no moving parts and nothing to block with leaf litter, on a tower visited a few times a year.

Range : 0 to 200 mm/hr, accuracy 5 percent, resolution 0.1 mm
Output : One pulse per 0.1 mm, into a contact-closure input
Limits : Liquid precipitation only, measurement range 0 to +70 degrees C

View TruMet PW100

Not sure which product fits this application?Tell us where it will be installed, what it has to survive and the system the data has to reach. Our team will narrow the range down with you.

Get expert advice

Where eddy covariance measurement does the work

Carbon flux

Ecosystem carbon exchange

Net ecosystem exchange over forest, grassland and cropland, where the record has to run for years to be worth anything.

Water flux

Evapotranspiration

Latent heat and water vapour exchange, used both for ecosystem science and to calibrate the models agriculture and hydrology run on.

Urban flux

City and suburban towers

Flux measurement over heterogeneous urban surfaces, where the footprint changes with direction and the sensor sees a different city each hour.

Energy balance

Closing the budget

Radiation, soil, sensible and latent heat terms measured together, because closure is how a flux dataset earns confidence.

Sub-canopy

Understorey exchange

Slow, sheltered, three-dimensional flow below the canopy, where head geometry matters more than top wind speed.

Method development

Instrument comparison

Side-by-side deployments and inter-comparison campaigns, where individual calibration and a known head geometry are the whole point.

UKAS-accredited calibration for six measurement parameters

Labcal is an independent UKAS-accredited calibration laboratory, Lab 0625, operating to ISO/IEC 17025:2017. It provides calibration across gas and air flow, air velocity, liquid flow, pressure, temperature and humidity, all under one roof.

For flux and reference measurement that includes anemometers, Pitot tubes and thermal probes, alongside pressure gauges and transducers, thermometers, temperature and humidity probes and data loggers. Labcal supports equipment from Gill and other manufacturers, which matters on a site where instruments arrived across twenty years and several projects.

01 · Gas and air flow

Gas meters · Mass flow controllers · Dispensing systems · Low-flow laboratory to higher-flow industrial

02 · Air velocity

Anemometers · Pitot tubes · Thermal probes

03 · Liquid flow

Flow meters and sensors · Process control equipment · Water used for the accredited capability

04 · Pressure

Gauges · Transducers · Manometers · Transmitters

05 · Temperature

Thermometers · Probes · Thermocouples · Data loggers

06 · Humidity

Hygrometers · Probes · Transmitters

One laboratory. Six UKAS-accredited parameters.Equipment from any manufacturer.
Explore Calibration Services

Getting 100 Hz data off the tower and into the record

A high-rate measurement is only useful once the acquisition system has it, sample-aligned with everything else on the tower.

Gill supports environmental monitoring, embedded electronics and systems integration to help research groups and instrument integrators bring measurement into existing loggers and acquisition systems without breaking a series that is already running.

RS422 is native on the Research range. RS232 and analogue outputs are available through the PCI or PCIA interface, which needs specifying alongside the instrument rather than after it.

Outputs and options

  • RS422 native : 14-bit digital at up to 100 Hz
  • RS232 & analogue : Through the PCI or PCIA interface
  • SDI-12 & Modbus : Reference and soil measurement on the same tower
  • MetSet & MetView : Free configuration, display and logging software

Why flux groups specify Gill

01

Rates the method actually needs

R3-100 and HS-100 at 100 Hz, R3-50 and HS-50 at 50 Hz, with wind speed accuracy under 1 percent and 0.01 m/s resolution.

02

Individual calibration as standard

Every Research range instrument is calibrated individually, so traceability is settled before the instrument reaches the tower.

03

Head geometry for the flow you have

Symmetrical for all-direction work, horizontal for vertical-flow analysis, with a built-in inclinometer on the HS models for tower set-up.

04

Power budgets that work on solar

9 to 30 V DC, under 4 W in operation, which is what makes an unattended tower viable.

05

Built to join an existing record

RS422 native with RS232 and analogue through the PCI interface, alongside SDI-12 and Modbus for the reference measurements.

06

Traceability that survives review

Independent UKAS-accredited calibration across six parameters, for equipment from any manufacturer.

Ready to specify?Talk through approvals, mounting, power and integration with our team before the specification is fixed.

Discuss your requirements

Questions about sensing for eddy covariance

Eddy covariance basics

Eddy covariance is a micrometeorological method for measuring the vertical exchange of a quantity such as carbon dioxide, water vapour or heat between a surface and the atmosphere. It works by measuring the vertical wind component and the quantity of interest at the same point, many times a second, and taking the covariance of the two over an averaging period, typically 30 minutes.

Because the transport happens in short-lived turbulent eddies rather than as a steady flow, the instrumentation has to resolve those eddies as they pass. That is what sets the requirement for fast 3-axis wind measurement rather than a conventional weather station.

The three-dimensional wind vector, at a rate fast enough to resolve the turbulent eddies carrying the flux, with a known and stable response. The vertical component is the one the flux calculation depends on, and it also needs sonic temperature from the same measurement so that the sensible heat flux and the density corrections can be derived from a single instrument.

Head geometry and calibration matter as much as the headline accuracy figure, because the sensor structure itself sits in the flow it is measuring.

High enough to resolve the turbulent structures carrying the flux, which for most surfaces means tens of hertz. The R3-50 and HS-50 output at 50 Hz and the R3-100 and HS-100 at 100 Hz.

Gill engineering insightRate first, accuracy second. An instrument that samples too slowly loses flux regardless of how accurate each sample is, and the correction for that loss becomes an assumption in the result.

Because the flux is a vertical transport, and the vertical wind component is the term the calculation is built on. A 2-axis anemometer measures horizontal speed and direction and simply does not produce the quantity the method needs.

Measuring all three axes at the same point also allows the coordinate rotation or planar fit that flux processing applies to correct for tilt and terrain, which cannot be done from horizontal wind alone.

Specification

Symmetrical for all-direction work where the footprint moves with the wind rose. Horizontal where accurate vertical-flow analysis matters and the sensor geometry itself would otherwise disturb the flow being measured.

Gill engineering insightThe HS models also carry a built-in inclinometer. Levelling a head accurately on a tower in wind is harder than the specification sheet implies, and this makes it a two-minute job.

The head is a physical object standing in the flow it measures, so its geometry decides which wind directions are disturbed by the structure and how much of the vertical component reaches the measurement path cleanly.

A symmetrical head accepts wind from all directions on equal terms, which suits sites where the footprint moves around the wind rose. A horizontal head opens up the vertical path, which suits work where vertical-flow analysis is the point and structural disturbance of that component has to be minimised. Neither is universally correct: the choice follows the site and the science.

Gill engineering insightWhichever geometry you choose, keep it for the life of the record. Changing head geometry mid-series is a change in the measurement, not just the instrument.

0 to 45 m/s across R3-50, R3-100, HS-50 and HS-100, with 0 to 359 degrees on direction. These are accuracy and data-rate instruments rather than storm-survival sensors.

The Research range runs from 9 to 30 V DC, drawing less than 150 mA at 24 V DC and under 4 W in operation. MetConnect runs from 5 to 30 V DC at less than 70 mA at 12 V DC.

Gill engineering insightOn a solar and battery tower the power budget usually decides the instrument list before anyone discusses specifications. Work it out at design stage, not after the tower is up.

RS422 is native on the Research range. RS232 and analogue outputs come through the PCI or PCIA interface, which needs to be specified alongside the instrument.

Research datasets

Match the output format and the calibration traceability, and where possible run the old and new instruments in parallel for a season so the relationship between them is measured rather than assumed.

Gill engineering insightA parallel season is cheap. Retrofitting a correction to twenty years of data is not, and it becomes a caveat in every paper that uses the record.

Because a flux dataset is used years after it is collected, often by people who were not there when it was collected, and its value depends on being able to say what the instrument was doing at the time. Calibration is what turns a plausible number into a defensible one.

The Research range is supplied with individual calibration as standard rather than a type figure, and Labcal is an independent UKAS-accredited laboratory, Lab 0625, operating to ISO/IEC 17025:2017. Recalibration on a stated interval gives the series a documented history rather than an assumption.

Set by the group and by what the data is used to argue. Where results are published or feed a network protocol, an annual traceable calibration is common.

Labcal is UKAS-accredited to ISO/IEC 17025:2017 and calibrates air velocity, temperature, humidity, pressure, and gas and liquid flow.

Radiation and soil heat terms alongside the turbulent fluxes. MetConnect takes a four-wire Pt100 to IEC 60751 and two analogue inputs, with 5 V available on the sensor connectors, so soil probes and a compatible radiometer can feed the same record.

Yes. MetConnect accepts a four-wire Pt100, two analogue inputs at 0 to 5 V or 4 to 20 mA, and a contact closure for a tipping-bucket rain input.

Choosing the instrument

Both measure three axes. The Research range goes to 50 or 100 Hz with individual calibration as standard, built for measurement quality. WindMaster tops out at 32 Hz and covers general 3-axis work and additional profile levels.

Start with the rate the science needs, then the head geometry, then the site temperature. The R3-50 and HS-50 output at 50 Hz, the R3-100 and HS-100 at 100 Hz. R3 heads are symmetrical, HS heads are horizontal and carry a built-in inclinometer for levelling on a tower.

Operating temperature is the specification that most often decides it. The R3-50, R3-100 and HS-50 operate from -40 to +60 degrees C. The HS-100 is 0 to +50 degrees C, so it is not the instrument for a cold-climate or high-altitude deployment.

Gill engineering insightCheck the temperature range against the site before choosing the HS-100. It is the specification that catches people out most often.

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

We aim to respond in one working day.