LevelSlick

For conductive liquids that coat, clog or corrode.

LevelSlick exists for the liquids the other sensors struggle with: conductive fluids carrying particles or suspended matter, and viscous or corrosive media. The FEP coating, with its non-stick and low friction properties, is the point of the product, because it is what stops the sensing surface fouling in service.

LevelSlick liquid level sensor

Lengths up to 2 m

Capacitive, no moving parts

FEP coating, non-stick and low friction

For difficult conductive liquids

BSP 1.25 inch thread

Voltage, current or resistive

-40 °C to +85 °C

Operating temperature

WHERE IT SITS

LevelSlick in the Level sensors range

Need a local readout? The DD1615 Level Display is the display accessory for the level sensor range.

SPECIFICATION IN BRIEF

What the LevelSlick provides

What it isSpecialist sensor for challenging conductive liquids
Suited toParticles, suspended matter, viscous and corrosive media
BuildFEP coating with non-stick and low friction properties, enclosed electronics
OutputsVoltage, current or resistive

SPECIFICATION

Full specification

Figures from the LevelSlick datasheet, issue 9. Confirm the current issue before ordering.

Measurement

What it isSpecialist sensor for challenging conductive liquids
Measurement rangeUp to 2 m
OptionsTank profiling, full and empty alarms
Suited toParticles, suspended matter, viscous and corrosive media

Outputs and power

OutputsVoltage, current or resistive
Supply voltage+6 to +32 V DC

Environment

Operating temperature-40 °C to +85 °C
Ingress protectionIP66, IP68 and IP69K

Mechanical

MaterialsFEP coating with non-stick and low friction properties, enclosed electronics
DimensionsBSP 1.25 inch thread

Approvals and documentation

DatasheetLevelSlick Iss 9

COMPARE

LevelSlick against LevelPro: only what differs

LevelSlickLevelPro
What it isSpecialist sensor for challenging conductive liquidsRobust general-purpose continuous liquid level sensor
BuildFEP coating with non-stick and low friction properties, enclosed electronicsCorrosion-resistant stainless steel, fully sealed
OutputsVoltage, current or resistiveCurrent or voltage (0 to 10 V, 4 to 20 mA), RS232 for configuration
DatasheetLevelSlick Iss 9LevelPro Iss 5

The nearest comparison in the range. Confirm which specification the application actually needs before ordering either. Compare the whole range

ACCESSORIES

LevelSlick accessories

The DD1615 display and calibration options for LevelSlick.

Displays

Calibration options

  • Additional liquid calibrationSpecify the liquid when ordering
  • Calibration certificateSpecify when ordering

Order accessories with your sensor or on their own. Quote the part number when you get in touch.

Get expert advice

BEFORE YOU SPECIFY

Is the LevelSlick the correct configuration?

Before specifying, confirm:

  • the measurement or level range the application needs
  • the output and interface the receiving system expects
  • the fluid or medium and its effect on the sensing surface
  • the environmental sealing the installation demands
  • the mounting arrangement and available space
  • any approval or certification the application requires

If those match, the LevelSlick provides that configuration.

QUESTIONS

Specification questions about the LevelSlick

What is the LevelSlick used for?

The LevelSlick measures challenging conductive liquids: fluids with particles or suspended matter, viscous fluids and corrosive liquids, such as waste water and corrosive storage.

Why does the LevelSlick have an FEP coating?

The FEP coating has non-stick and low friction properties, which stop dirty and viscous liquids building up on the probe, which would otherwise affect a capacitive reading. The electronics are fully enclosed.

Does the LevelSlick work with any liquid?

The LevelSlick is designed for electrically conductive liquids. Check the medium with our team before you specify it.

How long can a LevelSlick probe be?

The LevelSlick measures up to 2 m. It mounts on a BSP 1.25 inch thread.

Which outputs can the LevelSlick provide?

The LevelSlick is available with a voltage, current or resistive output. A current output uses a 250 Ohm load.

What temperature range does the LevelSlick operate over?

The LevelSlick operates from -40 °C to +85 °C.

Can the LevelSlick raise full and empty alarms?

Yes. The LevelSlick supports tank profiling and full and empty alarms.

Where can I find the LevelSlick datasheet?

The current datasheet is LevelSlick issue 9. It is linked in the Documents panel on this page and on the datasheets page.

At a glance
OutputsVoltage, current or resistive
Operating temperature-40 °C to +85 °C

Have an application to discuss?

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

Enquiring about LevelSlick

  • Our team replies. Not an account manager, and not a queue.
  • We aim to respond in one working day. Monday to Friday.
  • No obligation. Just honest advice on whether Gill is the right fit.