A turbine optimises to the wind it can measure.
So the sensor can’t be the part that fails.

Turbines depend on accurate wind data to yaw, pitch and shut down safely, and resource assessment relies on met masts measuring over long campaigns. Mechanical sensors wear, drift and ice up. Ultrasonic sensors with no moving parts keep the measurement, and the performance it drives, reliable.

1984
Building ultrasonic wind sensors in the UK
0
Moving parts to wear or drift
IP69K
WindUltra ingress protection rating
150+
Countries where Gill operates

A turbine can only optimise to the wind it can measure

Wind turbines depend on accurate wind data to yaw into the wind, adjust blade pitch and shut down safely in extreme conditions. Resource assessment relies on met masts measuring wind over long campaigns. In both cases the measurement is foundational, and in both cases a mechanical sensor is a liability.

Cup and vane anemometers wear, ice up and fail on nacelles and exposed masts, dragging down turbine performance and adding maintenance cost. Gill ultrasonic sensors have no moving parts, so the data your control and assessment depend on stays reliable.

Turbine control and safety

Yaw, pitch and safe shutdown all rely on accurate wind data. Bad readings cost performance or risk the asset.

Performance optimisation

Mechanical sensors that drift or fail reduce turbine output. A robust solid-state sensor protects yield.

Resource assessment

Met masts need consistent, accurate wind over long campaigns to underpin investment decisions.

Cold climate icing

Exposed turbines and masts face ice. Heated ultrasonic sensors keep measuring through it.

Technical
insight

A failing wind sensor quietly costs turbine performance

When a nacelle anemometer drifts or seizes, the turbine no longer yaws or pitches to the true wind. The loss does not announce itself, it shows up as reduced output and higher maintenance, often blamed on everything but the sensor.

Gill ultrasonic sensors measure wind with no moving parts, so they do not wear or drift the way mechanical units do. That protects both the control decisions and the performance they drive.

Wind instruments for turbines and met masts

Turbine control and resource assessment both need robust, accurate wind measurement that survives exposure. These products fit.

Gill WindObserver ultrasonic anemometer
Exposed masts and turbines

WindObserver

Robust stainless steel 2-axis anemometer

For exposed met masts and turbine installations, including cold climates. 316 stainless steel with optional heating to keep measuring through ice and snow.

Type2-axis ultrasonic
Build316 stainless steel
OptionsHeated for ice and snow

View WindObserver

Gill WindSonic ultrasonic anemometer range
Reliable control feedback

WindSonic

Cost-effective 2-axis anemometer

Dependable wind speed and direction for turbine control and monitoring, integrating easily and matching existing calibration requirements, with no moving parts to fail.

Type2-axis ultrasonic
Range0–60 m/s
OutputsRS232/422/485, Modbus, SDI-12

View WindSonic

Gill WindUltra ultrasonic anemometer
Compact and robust

WindUltra

Smallest, lightest 2-axis anemometer

Where size and weight matter on instrumentation, WindUltra gives high accuracy in a compact body, aggressively tested to IP69K for tough, exposed conditions.

Type2-axis ultrasonic
ProtectionIP69K
Best forCompact instrumentation fits

View WindUltra

Not sure which sensor fits your turbines or met mast?Tell us whether it is control, monitoring or resource assessment, and the climate. We’ll confirm the right specification.

Get application help

What this looks like on wind assets

Case 01 / Turbine performance

Gill and DC21 on turbine performance

Optimising turbine performance depends on reliable sensor data that the control system can trust.

Gill has worked with DC21 to enhance wind turbine performance with robust sensor technology, replacing the failure modes of mechanical units.

Case 02 / Replacing mechanical sensors

Ending repeated nacelle failures

Mechanical anemometers on nacelles fail, reducing turbine performance and adding maintenance cost.

Switching to a robust, solid-state ultrasonic sensor that integrates easily and matches existing calibration offers a dependable alternative.

Case 03 / Resource assessment

Confident met-mast campaigns

Investment decisions rest on long, accurate wind records from met masts at proposed sites.

Ultrasonic sensors deliver consistent measurement across long campaigns, with no wear-driven drift to undermine the dataset.

Case 04 / Cold climates

Measuring through ice and snow

Cold-climate wind sites are among the most punishing, and icing stops mechanical and unheated sensors alike.

Heated WindObserver units keep measuring through ice, protecting both safety shutdowns and performance data.

Built to feed turbine controllers and SCADA

Wind data has to reach turbine controllers, SCADA and data loggers cleanly. Gill sensors output in the standard formats those systems use, and match common calibration requirements for retrofit.

Where a project needs something specific, Gill R&D handles embedded software and systems integration in-house.

Outputs and options

  • ModbusFor SCADA and turbine control
  • RS232 / RS422 / RS485Serial outputs for controllers and loggers
  • SDI-12For met masts and monitoring networks
  • Heated variantsFor cold-climate sites
  • Analogue & digitalVoltage, current and digital options on selected sensors

Specifying wind sensors for wind energy

Mechanical sensors wear, drift and fail on nacelles, which reduces turbine performance and adds maintenance cost. A solid-state ultrasonic sensor removes that failure mode, integrates easily and can match existing calibration requirements, making retrofit straightforward.

WindObserver suits exposed met masts, with heating for cold climates, and delivers consistent measurement across long campaigns. We can advise on configuration to match your assessment methodology.

Yes. Heated WindObserver variants keep measuring through ice and snow, protecting both safe-shutdown decisions and performance data. Share the climate and we’ll recommend the configuration.

Outputs include Modbus, serial and analogue formats that cover most turbine controllers and SCADA systems, and the sensors can match common calibration requirements for retrofit. Where a project needs a bespoke integration, Gill R&D can help.

With no bearings, cups or vanes there is no scheduled mechanical maintenance and no wear parts to replace, which is exactly what nacelle and mast installations need. Periodic calibration checks keep data quality high.

Need calibration, integration or cold-climate detail?Calibration matching, output protocols, heated-variant and mounting detail. Direct from our engineering team.

Request technical info

Six reasons wind operators specify Gill

01

40 years of ultrasonic measurement

Gill brought ultrasonic anemometry to market and has refined it since 1984.

02

Protects turbine performance

No drift or wear means control decisions stay based on true wind.

03

Easy retrofit

Integrates easily and matches existing calibration requirements.

04

Built for exposure and ice

316 stainless steel and heated options for cold-climate masts and turbines.

05

Feeds control and SCADA

Modbus, serial and analogue outputs integrate with turbine and plant systems.

06

UK designed, made and supported

Engineered and manufactured in Lymington, Hampshire. Recipient of a King’s Award for Enterprise.

Send us an enquiry

Fill in your details below and our team will get back to you as soon as possible. If you can include whether it is turbine control, monitoring or resource assessment, plus the climate and the systems involved, we can respond with a specific recommendation faster.

* required field