News
Downloads
Careers
Home › Products › Weather stations › MetConnect › MetConnect One

FLEXIBLE PROFESSIONAL WEATHER STATION

MetConnect One

The variant with wind built in, using an integrated unheated WindSonic.

Who specifies it. Sites wanting MetConnect flexibility with wind supplied in the package, in climates without icing.

5 to 30 V DC3.0 kg
MetConnect One weather station

Integrated ultrasonic wind

0 to 60 m/s, ±2% RMS at 12 m/s

Temperature, RH and pressure

Separate by height, per WMO

316 stainless steel hub box

Fits a 30 to 58 mm pole or mast

Third-party sensor inputs

Pt100, analogue, contact closure

WHERE IT SITS

MetConnect One in the MetConnect range

MetConnect OneThe variant with wind built in, using an integrated unheated WindSonic.
MetConnect THPNo integrated wind, so wind comes from a connected Gill anemometer of your choice.View MetConnect THP

SPECIFICATION

Full specification

Figures from the MetConnect One datasheet, issue 2. Confirm the current issue before ordering.

Measurement

Wind speed range0 to 60 m/s
Wind direction0 to 360 degrees, accuracy plus or minus 3 degrees at 12 m/s
Temperature-35 degrees C to +70 degrees C, accuracy 0.2 degrees C from -35 degrees C to +50 degrees C, resolution 0.1 degrees C
Relative humidity0 to 100% RH, accuracy 1.5% RH at 25 degrees C over 0 to 80% RH, typically 2% from 35 degrees C to 70 degrees C, resolution 1% RH
Barometric pressure300 to 1100 hPa, accuracy plus or minus 0.5 hPa from 0 to 50 degrees C, resolution 0.1 hPa
Integrated sensorsWind speed and direction, temperature, humidity, pressure
Additional inputsWind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 probe to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA, loop or self-powered
AccuracyTemperature 0.2 °C, relative humidity 1.5% RH at 25 °C over 0 to 80% RH, barometric pressure ±0.5 hPa over 0 to 50 °C, wind speed ±2% RMS at 12 m/s, wind direction ±3° at 12 m/s
Wind speed accuracyPlus or minus 2% RMS at 12 m/s
ResolutionTemperature 0.1 °C, relative humidity 1% RH, barometric pressure 0.1 hPa
ConnectivityM12 8-way connectors on all inputs and outputs
MechanicalStainless steel 316 hub box, fits a 30 to 58 mm pole or mast, 3.0 kg
SoftwareMetSet for configuration and MetView for display and logging, both free
OptionsMetSet configuration software and MetView display and logging software. Pairs with the TruMet PW100
WindIntegrated WindSonic, 0 to 60 m/s, unheated

Outputs and power

Output rateOne measurement per 1, 2 or 4 seconds, or polled
OutputsRS232, RS422, RS485 2-wire point to point, Modbus, SDI-12
InterfaceM12 8-way connectors throughout. Wind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA
ProtocolsASCII, Modbus RTU and ASCII, NMEA0183, SDI-12 v1.3
Supply voltage5 to 30 V DC
Power5 to 30 V DC, under 70 mA at 12 V DC
Power consumptionUnder 70 mA at 12 V DC
Sensor input power5 V available on the additional sensor input connectors

Environment

Operating temperature-35 degrees C to +70 degrees C, storage -40 degrees C to +70 degrees C
Ingress protectionHub box and pressure sensor IP66 and IP67, temperature and humidity sensor IP66, wind sensor IP66
HeatingNot offered. The integrated WindSonic is unheated

Mechanical

MaterialsStainless steel 316 hub box
Weight3.0 kg

Approvals and documentation

CertificationsEMC EN 61326:2013. CE, UKCA, FCC Part 15 and RoHS
Datasheet1733-0001 Iss 2

COMPARE

MetConnect One against MetConnect THP: only what differs

MetConnect OneMetConnect THP
Integrated sensorsWind speed and direction, temperature, humidity, pressureTemperature, humidity, pressure
WindIntegrated WindSonic, 0 to 60 m/s, unheatedNo integrated wind, taken from a connected Gill anemometer
Datasheet1733-0001 Iss 21733-0002 Iss 1

MetConnect One against the two models a buyer most often looks at alongside it. The whole range is on the MetConnect page. Compare the whole range

ACCESSORIES

Accessories for the MetConnect One

The parts that fit the MetConnect One: cable, mounting, set-up kit and spares.

Cables

  • Power and comms cable, 2 m, M12 fittedPart no. 1733-PK-011 2 m
  • Power and comms cable, 10 m, M12 fittedPart no. 1733-PK-013 10 m
  • Power and comms cable, 20 m, M12 fittedPart no. 1733-PK-014 20 m
  • Cable, 4 pair, cut to lengthPart no. 1733-PK-010 Per metre

Connectors

  • M12 connector, 8 way, field wireablePart no. 1733-PK-002

Mounting

  • Bracket mounting kitPart no. 1733-PK-022 For re-mounting

Set-up and configuration

  • M12 to USB adaptorPart no. 1733-PK-030
  • M12 to USB adaptor cablePart no. 1733-PK-031

Spares

  • Replacement pressure sensorPart no. 1733-PK-040
  • Replacement temperature and humidity sensorPart no. 1733-PK-041

Order accessories with your sensor or on their own. Quote the part number when you get in touch. See the accessories datasheet

Get expert advice

QUESTIONS

Specification questions about the MetConnect One

Which parameters does the MetConnect One measure?

The MetConnect One measures wind direction, temperature, relative humidity, barometric pressure and wind.

What sensors are integrated in the MetConnect One?

Wind speed and direction, temperature, humidity, pressure.

What inputs does the MetConnect One accept?

The MetConnect One accepts wind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 probe to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA, loop or self-powered.

How accurate is the MetConnect One?

The MetConnect One is specified at temperature 0.2 °C, relative humidity 1.5% RH at 25 °C over 0 to 80% RH, barometric pressure ±0.5 hPa over 0 to 50 °C, wind speed ±2% RMS at 12 m/s, wind direction ±3° at 12 m/s.

What resolution does the MetConnect One report?

The MetConnect One reports to temperature 0.1 °C, relative humidity 1% RH, barometric pressure 0.1 hPa.

What output rate does the MetConnect One provide?

The MetConnect One outputs at one measurement per 1, 2 or 4 seconds, or polled.

What outputs does the MetConnect One provide?

The MetConnect One provides RS232, RS422, RS485 2-wire point to point, Modbus, SDI-12.

What power supply does the MetConnect One need?

The MetConnect One requires 5 to 30 V DC.

At a glance
Wind speed accuracyPlus or minus 2% RMS at 12 m/s
Supply voltage5 to 30 V DC
Weight3.0 kg

Have an application to discuss?

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

Enquiring about MetConnect One

  • Our team replies. Not an account manager, and not a queue.
  • We aim to respond in one working day. Monday to Friday.
  • No obligation. Plenty of these end with us saying it is not our product.