FLEXIBLE PROFESSIONAL WEATHER STATION
MetConnect THP
No integrated wind, so wind comes from a connected Gill anemometer of your choice.
Who specifies it. Sites needing wind at a different height, a heated anemometer, or a specific Gill wind sensor.

Temperature, RH and pressure
Pressure accurate to ±0.5 hPa
316 stainless hub box
Fits 30 to 58 mm poles
Modbus, SDI-12, NMEA 0183
RS232, RS422 or RS485
5 to 30 V DC
Separable sensors, one hub
WHERE IT SITS
MetConnect THP in the MetConnect range
SPECIFICATION
Full specification
Figures from the MetConnect THP datasheet, issue 1. Confirm the current issue before ordering.
Measurement
| Temperature | -35 degrees C to +70 degrees C, accuracy 0.2 degrees C from -35 degrees C to +50 degrees C, resolution 0.1 degrees C |
|---|---|
| Relative humidity | 0 to 100% RH, accuracy 1.5% RH at 25 degrees C over 0 to 80% RH, typically 2% from 35 degrees C to 70 degrees C, resolution 1% RH |
| Barometric pressure | 300 to 1100 hPa, accuracy plus or minus 0.5 hPa from 0 to 50 degrees C, resolution 0.1 hPa |
| Integrated sensors | Temperature, humidity, pressure |
| Additional inputs | Wind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 probe to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA, loop or self-powered |
| Accuracy | Temperature 0.2 °C, relative humidity 1.5% RH at 25 °C over 0 to 80% RH, barometric pressure ±0.5 hPa over 0 to 50 °C |
| Resolution | Temperature 0.1 °C, relative humidity 1% RH, barometric pressure 0.1 hPa |
| Connectivity | M12 8-way connectors on all inputs and outputs |
| Mechanical | Stainless steel 316 hub box, fits a 30 to 58 mm pole or mast, 3.0 kg |
| Software | MetSet for configuration and MetView for display and logging, both free |
| Options | Wind from a connected Gill anemometer. MetSet configuration software and MetView display and logging software. Pairs with the TruMet PW100 |
| Wind | No integrated wind sensor, wind comes from a connected Gill anemometer |
Outputs and power
| Output rate | One measurement per 1, 2 or 4 seconds, or polled |
|---|---|
| Outputs | RS232, RS422, RS485 2-wire point to point, Modbus, SDI-12 |
| Interface | M12 8-way connectors throughout. Wind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA |
| Protocols | ASCII, Modbus RTU and ASCII, NMEA0183, SDI-12 v1.3 |
| Supply voltage | 5 to 30 V DC |
| Power | 5 to 30 V DC, under 70 mA at 12 V DC |
| Power consumption | Under 70 mA at 12 V DC |
| Sensor input power | 5 V available on the additional sensor input connectors |
Environment
| Operating temperature | -35 degrees C to +70 degrees C, storage -40 degrees C to +70 degrees C |
|---|---|
| Ingress protection | Hub box and pressure sensor IP66 and IP67, temperature and humidity sensor IP66, wind sensor IP66 |
| Heating | No integrated wind sensor. Cold-climate capable when paired with a heated WindObserver or WindSonic M |
Mechanical
| Materials | Stainless steel 316 hub box |
|---|---|
| Weight | 3.0 kg |
Approvals and documentation
| Certifications | EMC EN 61326:2013. CE, UKCA, FCC Part 15 and RoHS |
|---|---|
| Datasheet | 1733-0002 Iss 1 |
COMPARE
MetConnect THP against MetConnect One: only what differs
| MetConnect THP | MetConnect One | |
|---|---|---|
| Integrated sensors | Temperature, humidity, pressure | Wind speed and direction, temperature, humidity, pressure |
| Wind | No integrated wind, taken from a connected Gill anemometer | Integrated WindSonic, 0 to 60 m/s, unheated |
| Datasheet | 1733-0002 Iss 1 | 1733-0001 Iss 2 |
MetConnect THP against the two models a buyer most often looks at alongside it. The whole range is on the MetConnect page. Compare the whole range
ACCESSORIES
Accessories for the MetConnect THP
The parts that fit the MetConnect THP: cable, mounting, set-up kit and spares.
Cables
- Power and comms cable, 2 m, M12 fitted
- Power and comms cable, 10 m, M12 fitted
- Power and comms cable, 20 m, M12 fitted
- Cable, 4 pair, cut to length
Connectors
- M12 connector, 8 way, field wireable
Mounting
- Bracket mounting kit
Set-up and configuration
- M12 to USB adaptor
- M12 to USB adaptor cable
Spares
- Replacement pressure sensor
- Replacement temperature and humidity sensor
Order accessories with your sensor or on their own. Quote the part number when you get in touch. See the accessories datasheet
QUESTIONS
Specification questions about the MetConnect THP
Which parameters does the MetConnect THP measure?
The MetConnect THP measures temperature, relative humidity, barometric pressure and wind.
What sensors are integrated in the MetConnect THP?
Temperature, humidity, pressure.
What inputs does the MetConnect THP accept?
The MetConnect THP accepts wind input for a Gill anemometer, contact closure for a tipping-bucket rain gauge, 4-wire Pt100 probe to IEC 60751, and two analogue inputs at 0 to 5 V or 4 to 20 mA, loop or self-powered.
How accurate is the MetConnect THP?
The MetConnect THP is specified at temperature 0.2 °C, relative humidity 1.5% RH at 25 °C over 0 to 80% RH, barometric pressure ±0.5 hPa over 0 to 50 °C.
What resolution does the MetConnect THP report?
The MetConnect THP reports to temperature 0.1 °C, relative humidity 1% RH, barometric pressure 0.1 hPa.
What output rate does the MetConnect THP provide?
The MetConnect THP outputs at one measurement per 1, 2 or 4 seconds, or polled.
What outputs does the MetConnect THP provide?
The MetConnect THP provides RS232, RS422, RS485 2-wire point to point, Modbus, SDI-12.
What power supply does the MetConnect THP need?
The MetConnect THP requires 5 to 30 V DC.
Have an application to discuss?
Speak to our team
Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.
Enquiring about MetConnect THP
- Our team replies. Not an account manager, and not a queue.
- We aim to respond in one working day. Monday to Friday.
- No obligation. Plenty of these end with us saying it is not our product.