News
Downloads
Careers
Home › Products › Wind sensors › WindObserver › WindObserver 65

PRECISION ULTRASONIC WIND SENSOR

WindObserver 65

Precision wind measurement with selectable output rate.

WindObserver 65 is the WindObserver with the widest choice of output rate, from 1 Hz to 10 Hz. That makes it the option where the receiving system needs a faster update than the rest of the range provides, within a 0 to 65 m/s measurement range.

IP66 (NEMA 4X)1, 2, 4, 5, 8 or 10 HzAnemometer 9 to 30 V DC1.4 kg
Lloyd's Register Type Approved mark
WindObserver 65 2-axis ultrasonic anemometer

Open-head design

Accurate at steep flow angles

Up to 65 m/s

Output rate up to 10 Hz

Stainless steel 316

Sealed to IP66, NEMA 4X

Lloyd’s Register approved

Marine type approval

WHERE IT SITS

WindObserver 65 in the WindObserver range

Within the WindObserver family the models differ by measurement range, output rate, build and approvals rather than by measurement principle.

MEASUREMENT

What the WindObserver 65 measures

The WindObserver 65 is a precision 2-axis ultrasonic anemometer.

Wind speed0 to 65 m/s (145 mph)
Output rate1, 2, 4, 5, 8 or 10 Hz

SPECIFICATION

Full specification

Figures from the WindObserver 65 datasheet, issue 10. Confirm the current issue before ordering.

Measurement

Wind speed0 to 65 m/s (145 mph)
Direction range0 to 360°, no dead band
AccuracyWind speed ±2% at 12 m/s, direction ±2° at 12 m/s
Resolution0.01 m/s and 1°
OptionsHeating. Calibration traceable to national standards

Outputs and power

Output rate1, 2, 4, 5, 8 or 10 Hz
OutputsRS422 and RS485, full or half duplex. Modbus output variant available
InterfaceRS422 or RS485, full or half duplex, baud 1200 to 38400
Supply voltageAnemometer 9 to 30 V DC
Power consumptionAnemometer 30 mA at 12 V DC. Optional heating 3 A at 24 V AC or DC

Environment

Ingress protectionIP66 (NEMA 4X)
HeatingOptional anti-icing, 3 A at 24 V AC or DC

Mechanical

MaterialsStainless steel 316
Weight1.4 kg

Approvals and documentation

CertificationsLloyd’s Register Type Approved. EMC EN 61326-1:2013 and EN 60945:2002. Icing tested to MIL-STD-810F
Datasheet1390-0036 Iss 10

COMPARE

WindObserver 65 against WindObserver 75: only what differs

WindObserver 65WindObserver 75
Wind speed0 to 65 m/s (145 mph)0 to 75 m/s (168 mph)
Output rate1, 2, 4, 5, 8 or 10 Hz1 to 4 Hz
Weight1.4 kg1.7 kg with 2 m cable, 1.3 kg with connector
Datasheet1390-0036 Iss 101390-0034 Iss 10
Show the 1 rows that are the same
WindObserver 65WindObserver 75
ApprovalsLloyd’s Register Type ApprovedLloyd’s Register Type Approved

The nearest sibling in the range. Confirm which specification the application actually needs before ordering either. Compare the whole range

ACCESSORIES

Accessories for the WindObserver 65

The parts that fit the WindObserver 65: cable, mounting, set-up kit and spares.

Chosen at order. The base connector, cable gland and base mount are part of the WindObserver order code. The parts below are for installation, set-up and spares.

Cables

  • Cable, 9 pair, cut to lengthPart no. 026-02663 Per metre

Connectors

  • Connector kitPart no. 1390-10-163

Mounting

  • Bracket for pole or wall mountingPart no. 1771-PK-116
  • Base mount, shortPart no. 1390-PK-176
  • Base mount, longPart no. 1390-PK-177
  • Base mount pipe adaptorPart no. 1390-PK-178

Set-up and configuration

  • USB to RS422, RS485 and RS232 adaptorPart no. 019-06272

Spares

  • Bird deterrent kitPart no. 1390-PK-251
  • Integrity check chamberPart no. 1277-00-052

Order accessories with your sensor or on their own. Quote the part number when you get in touch.

Get expert advice

BEFORE YOU SPECIFY

Is the WindObserver 65 the correct configuration?

Before specifying, confirm:

  • the wind speed range the site actually sees
  • the output rate the receiving system needs
  • the operating temperature and whether heating is required
  • any approval or certification the installation demands
  • the mounting arrangement and cable or connector choice
  • the interface and output the receiving system expects

If those match, the WindObserver 65 provides that configuration.

QUESTIONS

Specification questions about the WindObserver 65

What wind speed range does the WindObserver 65 cover?

The WindObserver 65 measures 0 to 65 m/s (145 mph).

What is the difference between the WindObserver 65 and the WindObserver 75?

The WindObserver 65 measures up to 65 m/s (145 mph) with output rates of 1, 2, 4, 5, 8 or 10 Hz, and weighs 1.4 kg. The WindObserver 75 measures up to 75 m/s (168 mph) at 1 to 4 Hz, and weighs 1.7 kg with 2 m of cable or 1.3 kg with a connector.

How accurate is the WindObserver 65?

The WindObserver 65 is specified at wind speed ±2% at 12 m/s, direction ±2° at 12 m/s.

What resolution does the WindObserver 65 report?

The WindObserver 65 reports to 0.01 m/s and 1°.

What output rate does the WindObserver 65 provide?

The WindObserver 65 outputs at 1, 2, 4, 5, 8 or 10 Hz.

What outputs does the WindObserver 65 provide?

The WindObserver 65 provides RS422 and RS485, full or half duplex. Modbus output variant available.

What power supply does the WindObserver 65 need?

The WindObserver 65 requires anemometer 9 to 30 V DC.

What ingress protection does the WindObserver 65 have?

The WindObserver 65 is sealed to IP66 (NEMA 4X).

At a glance
Wind speed0 to 65 m/s (145 mph)
Output rate1, 2, 4, 5, 8 or 10 Hz
Weight1.4 kg
ApprovalsLloyd’s Register Type Approved
Datasheet1390-0036 Iss 10
Supply voltageAnemometer 9 to 30 V DC
Ingress protectionIP66 (NEMA 4X)

Have an application to discuss?

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

Enquiring about WindObserver 65

  • Our team replies. Not an account manager, and not a queue.
  • We aim to respond in one working day. Monday to Friday.
  • No obligation. Plenty of these end with us saying it is not our product.