News
Downloads
Careers
Home › Products › Compare

COMPARE

Compare Gill products

Start with the problem, then compare the options side by side.

You do not need to know our product names. Pick what you are trying to measure, and each table shows what every option is best for, when to choose it, and how the specifications compare. Prefer to answer questions instead? The product finder does the narrowing for you.

START WITH THE PROBLEM

What are you trying to measure?

Each table starts with what every option is best for and when to choose it, then lines up the specifications. Tables scroll sideways on a small screen. Not stated means the datasheet does not give the figure.

WIND

Wind speed and direction on masts, buildings and vehicles

The everyday job. The choice comes down to how strong the wind gets, how much space and weight you have, and whether you want a compass built in.

Best forGeneral wind monitoringWindSonicStorm-force windsWindSonic 75Small, light or mobileWindUltraWind with a built-in compassGMX200
Choose it whenYou need reliable wind speed and direction and the site does not need heating or special approvals.Winds above 60 m/s are part of the site, but you do not need a heated stainless sensor.Space or weight is tight: drones, uncrewed vessels, vehicles, or anywhere the sensor needs IP68 and IP69K protection.You want a wind station with an integrated compass and optional GPS, for example on a vehicle.
Wind speed range0 to 60 m/s (116 knots)0 to 75 m/s (146 knots)0 to 75 m/s (168 mph, 270 km/h)Not stated
Wind speed accuracy2% RMSE @ 12 m/s±2% RMSE @ 12 m/s<2% RMSE or 0.1 m/s (0 to 20 m/s); <3% RMSE (>20 m/s)Not stated
Wind direction range0-360° (no dead band)0-360° (no dead band)0-360°Not stated
Wind direction accuracy2° RMSE @ 12 m/s±2° RMSE @ 12 m/s<1° RMSE (0 to 20 m/s); <2° RMSE (>20 m/s)Not stated
Resolution0.01 m/s, 1° (Option 4 SDI-12) / 0.1° (Options 1-3 ASCII)0.01 m/s, 0.1° (Options 1-3) / 1° (Option 5)0.01 m/s, 1°Not stated
ConstructionLuran S KR 2861/1C ASA/PC polycarbonateLuran S KR 2861/1C ASA/PC polycarbonateThermoplastic and marine-grade stainless steelNot stated
Weight0.5 kg0.5 kg260-270 g (with pole mount)0.5 kg
IP ratingIP66IP66IP69k, IP68, IP66 (EN 60529:1992)IP66
Operating temperature-35°C to +70°C-35°C to +70°C-40°C to +70°CNot stated
Output rate0.25, 0.5, 1, 2 or 4 HzNot statedNot statedNot stated
Output optionsRS232, RS422, RS485, SDI-12, Modbus RTU 2-wire RS-485, analogue 0-5 V, 0-20 mA or 4-20 mARS232, RS422, RS485 (Options 1-3), Modbus RTU (Option 5), analogue 0-5V or 4-20mARS-485 (ASCII, Modbus RTU), RS-422 (NMEA 0183), SDI-12Not stated
ProtocolsASCII, NMEA 0183, SDI-12 v1.3, Modbus RTUASCII, NMEA 0183, Modbus RTUNot statedNot stated
Power5-30 VDC or 9-30 VDC depending on output option; <2 mA @ 12V (SDI-12) to 44 mA @ 12V (4-20 mA)12-30 VDC (Options 1-3); 9-30 VDC (Option 5)5-30 VDC; under 100 mW to 800 mW unheated; under 7.6 W heatedNot stated
Warranty24 months24 monthsNot statedNot stated
WMO complianceNot statedWMO-compliant gust calculated from rolling averageNot statedNot stated
Response timeNot statedNot stated0.125 secondsNot stated
SizeNot statedNot stated84 mm diameter; 107-189 mm height (depending on mount)Not stated
HeatingNot statedNot statedConfigurable low-power, under 7.6 W heatedNot stated
ConnectorNot statedNot statedM12 8-wayNot stated
Configuration portNot statedNot statedUSB 2.0 Micro BNot stated
StandardsNot statedNot statedCE, UKCA, FCC Part 15, BS EN 61326:2013, BS EN 60945:2002, RoHSNot stated
Measured parametersNot statedNot statedNot statedWind speed and direction
Wind rangeNot statedNot statedNot stated0 to 60 m/s
Wind accuracyNot statedNot statedNot stated±0.3 m/s (0 to 10 m/s); ±3% (10-40); ±5% (40-60)
CompassNot statedNot statedNot stated2-axis (integrated)
GPSNot statedNot statedNot statedOptional
Operating tempNot statedNot statedNot stated-35°C to +70°C
OutputsNot statedNot statedNot statedRS232, RS422, RS485, SDI-12, NMEA, MODBUS
DatasheetDatasheetDatasheetDatasheetDatasheet

WIND

Wind at sea, on vessels and offshore

Salt, spray and motion. These are the options built to survive it, from a compact sensor for small craft to stainless steel for ships and platforms.

Best forCoastal sites and smaller vesselsWindSonic MSmall craft and uncrewed vesselsWindUltraShips and platformsWindObserver 65Ships with analogue systemsWindObserver IIWind on a vesselGMX260
Choose it whenA plastic body would not stand up to salt and spray, and winds stay within 60 m/s.Space and weight are tight, or the sensor needs IP68 and IP69K protection.You need stainless steel and optional de-icing for commercial marine use, with Lloyd's Register type approval.The vessel's system takes 4-20 mA or voltage, and you need Lloyd's Register type approval.You need wind on a moving platform, with a 6-axis compass and protection against submersion.
Wind speed range0 to 60 m/s (116 knots)0 to 75 m/s (168 mph, 270 km/h)0 to 65 m/s (145 mph)0 to 65 m/s (145 mph)Not stated
Wind speed accuracy±2% RMSE @ 12 m/s<2% RMSE or 0.1 m/s (0 to 20 m/s); <3% RMSE (>20 m/s)<2% RMSE @ 12 m/s<2% RMSE @ 12 m/sNot stated
Wind direction range0-360° (no dead band)0-360°0-360° (no dead band)0-360°Not stated
Wind direction accuracy±2° RMSE @ 12 m/s<1° RMSE (0 to 20 m/s); <2° RMSE (>20 m/s)<2° RMSE @ 12 m/s<2° RMSE @ 12 m/sNot stated
Resolution0.01 m/s, 0.1°0.01 m/s, 1°0.01 m/s, 1°0.01 m/s, 1°Not stated
ConstructionAl Alloy 6061 T6, hard anodisedThermoplastic and marine-grade stainless steel316 stainless steel316 stainless steelNot stated
Weight0.9 kg260-270 g (with pole mount)1.4 kgBeing confirmed0.5 kg
IP ratingIP66 (BS EN 60529:1992)IP69k, IP68, IP66 (EN 60529:1992)IP66 (NEMA4X)IP66 (NEMA4X)IP66 and IP68
Operating temperature-40°C to +70°C (with heating); -35°C to +70°C (without)-40°C to +70°C-55°C to +70°C (with heating)-55°C to +70°C (with heating)Not stated
Output optionsRS232, RS422, RS485, analogue 0-5V or 0-20mA or 4-20mARS-485 (ASCII, Modbus RTU), RS-422 (NMEA 0183), SDI-12Not statedNot statedNot stated
ProtocolsASCII, NMEA 0183Not statedModbus RTUNot statedNot stated
HeatingOptional, 24V AC/DC, 4.2 A @ 24VConfigurable low-power, under 7.6 W heatedOptional 3A @ 24 VAC/DCOptional 3A @ 24 VAC/DCNot stated
StandardsBS EN 60945:2002 vibration and compass safe distance, UL2218 Class 1 impactCE, UKCA, FCC Part 15, BS EN 61326:2013, BS EN 60945:2002, RoHSNot statedNot statedNot stated
WMO complianceWMO-compliant gust calculated from rolling averageNot statedRolling average and 3-second gust to WMO No. 8Not statedNot stated
Warranty24 monthsNot statedNot statedNot statedNot stated
Response timeNot stated0.125 secondsNot statedNot statedNot stated
SizeNot stated84 mm diameter; 107-189 mm height (depending on mount)Not statedNot statedNot stated
PowerNot stated5-30 VDC; under 100 mW to 800 mW unheated; under 7.6 W heatedNot statedNot statedNot stated
ConnectorNot statedM12 8-wayNot statedNot statedM12 8-way (corrosion-resistant)
Configuration portNot statedUSB 2.0 Micro BNot statedNot statedNot stated
Power (anemometer only)Not statedNot stated9-30 VDC, 30 mA @ 12 VDC9-30 VDC, 40 mA @ 12 VDCNot stated
OutputsNot statedNot statedRS422 / RS485 full or half duplexRS422 / RS485 full or half duplexRS232, RS422, RS485, SDI-12, NMEA, MODBUS
Output rateNot statedNot stated1, 2, 4, 5, 8 or 10 Hz1, 2, 4, 5, 8 or 10 HzNot stated
ParametersNot statedNot statedUV, Polar, NMEA, TunnelNot statedNot stated
Analogue outputsNot statedNot statedNot stated3 channels (speed, direction, status or sonic temperature); ±2.5 V, 0-5 V or 4-20 mA; scales in multiples of ±10 m/s up to ±70Not stated
CertificationsNot statedNot statedNot statedLloyd's Register type approval; ABS Product Design AssessedNot stated
Measured parametersNot statedNot statedNot statedNot statedWind speed and direction
Wind rangeNot statedNot statedNot statedNot stated0 to 60 m/s
CompassNot statedNot statedNot statedNot stated6-axis (with tilt, pitch, roll)
GPSNot statedNot statedNot statedNot statedOptional
Operating tempNot statedNot statedNot statedNot stated-35°C to +70°C
DatasheetDatasheetDatasheetDatasheetDatasheetDatasheet

WIND

Wind in ice, storms and extreme conditions

When the sensor has to keep working through icing or survive storm-force wind. The choice is how cold, how windy, and how much power you have for heating.

Best forCold, moderate windWindSonic MCold, compact and low powerWindUltraIcing, up to 65 m/sWindObserver 65Icing, high wind, turbine controlWindObserver 75The most extreme windsWindObserver 90
Choose it whenIcing down to -40°C is the issue, but winds stay within 60 m/s.You need heating down to -40°C and winds up to 75 m/s, with little space or power available.You need stainless steel and optional 3 A de-icing.Winds reach 75 m/s in cold climates, or the reading drives turbine yaw and pitch.Survival in storms up to 90 m/s matters most: high-altitude turbines, polar sites, offshore platforms.
Wind speed range0 to 60 m/s (116 knots)0 to 75 m/s (168 mph, 270 km/h)0 to 65 m/s (145 mph)0 to 75 m/s (168 mph)0 to 90 m/s (201 mph)
Wind speed accuracy±2% RMSE @ 12 m/s<2% RMSE or 0.1 m/s (0 to 20 m/s); <3% RMSE (>20 m/s)<2% RMSE @ 12 m/s<2% RMSE @ 12 m/s; ±1% within ±25° of datum for turbine control±2% @ 12 m/s; ±4% @ 90 m/s
Wind direction range0-360° (no dead band)0-360°0-360° (no dead band)0-360° (no dead band)0-360° (no dead band)
Wind direction accuracy±2° RMSE @ 12 m/s<1° RMSE (0 to 20 m/s); <2° RMSE (>20 m/s)<2° RMSE @ 12 m/s<2° RMSE @ 12 m/s; ±1° for turbine control±2° @ 12 m/s
Resolution0.01 m/s, 0.1°0.01 m/s, 1°0.01 m/s, 1°0.01 m/s, 1°0.01 m/s, 1°
ConstructionAl Alloy 6061 T6, hard anodisedThermoplastic and marine-grade stainless steel316 stainless steel316 stainless steel316 stainless steel
Weight0.9 kg260-270 g (with pole mount)1.4 kg1.7 kg (with 2m cable); 1.3 kg (with connector)1.7 kg (with 2m cable); 1.3 kg (with connector)
IP ratingIP66 (BS EN 60529:1992)IP69k, IP68, IP66 (EN 60529:1992)IP66 (NEMA4X)IP66 (NEMA4X)IP66 (NEMA4X)
Operating temperature-40°C to +70°C (with heating); -35°C to +70°C (without)-40°C to +70°C-55°C to +70°C (with heating)-55°C to +70°C (with heating)-55°C to +70°C (with heating)
Output optionsRS232, RS422, RS485, analogue 0-5V or 0-20mA or 4-20mARS-485 (ASCII, Modbus RTU), RS-422 (NMEA 0183), SDI-12Not statedNot statedNot stated
ProtocolsASCII, NMEA 0183Not statedModbus RTUNot statedNot stated
HeatingOptional, 24V AC/DC, 4.2 A @ 24VConfigurable low-power, under 7.6 W heatedOptional 3A @ 24 VAC/DC7 A @ 24 VAC/DC (1 W/cm², approx 150 W)7 A @ 24 VAC/DC (1 W/cm², approx 150 W)
StandardsBS EN 60945:2002 vibration and compass safe distance, UL2218 Class 1 impactCE, UKCA, FCC Part 15, BS EN 61326:2013, BS EN 60945:2002, RoHSNot statedNot statedNot stated
WMO complianceWMO-compliant gust calculated from rolling averageNot statedRolling average and 3-second gust to WMO No. 8Rolling average and 3-second gust to WMO No. 8Not stated
Warranty24 monthsNot statedNot statedNot statedNot stated
Response timeNot stated0.125 secondsNot statedNot statedNot stated
SizeNot stated84 mm diameter; 107-189 mm height (depending on mount)Not statedNot statedNot stated
PowerNot stated5-30 VDC; under 100 mW to 800 mW unheated; under 7.6 W heatedNot statedNot statedNot stated
ConnectorNot statedM12 8-wayNot statedNot statedNot stated
Configuration portNot statedUSB 2.0 Micro BNot statedNot statedNot stated
Power (anemometer only)Not statedNot stated9-30 VDC, 30 mA @ 12 VDCNot statedNot stated
OutputsNot statedNot statedRS422 / RS485 full or half duplexRS422 / RS485 full or half duplexRS422 / RS485 full or half duplex
Output rateNot statedNot stated1, 2, 4, 5, 8 or 10 Hz1 to 4 Hz1 to 4 Hz
ParametersNot statedNot statedUV, Polar, NMEA, TunnelNot statedNot stated
Icing standardNot statedNot statedNot statedMIL-STD-810F Method 521.2 Procedure IMIL-STD-810F Method 521.2 Procedure I
CalibrationNot statedNot statedNot statedNot statedCalibrated in Merlin Wind Tunnel, traceable to national standards
DatasheetDatasheetDatasheetDatasheetDatasheetDatasheet

WIND

Wind at airports and helipads

Start with one question: is the reading used for official wind reporting? If it is, it has to be FAA and CAA accepted.

Best forOfficial wind reportingWindObserver 70Aviation supportWindObserver 65Exposed, extreme airfieldsWindObserver 90
Choose it whenThe reading is used for AWOS surface wind reporting and must be FAA and CAA accepted. This is the only option that is.You need rugged, de-iced wind data around the airfield, but not for official FAA or CAA reporting.The site sees storm winds up to 90 m/s and the sensor has to survive them.
Wind speed range0 to 70 m/s (156 mph)0 to 65 m/s (145 mph)0 to 90 m/s (201 mph)
Wind speed accuracy<2% RMSE @ 12 m/s<2% RMSE @ 12 m/s±2% @ 12 m/s; ±4% @ 90 m/s
Wind direction range0-360° (no dead band)0-360° (no dead band)0-360° (no dead band)
Wind direction accuracy<2° RMSE @ 12 m/s<2° RMSE @ 12 m/s±2° @ 12 m/s
Resolution0.01 m/s, 1°0.01 m/s, 1°0.01 m/s, 1°
Construction316 stainless steel316 stainless steel316 stainless steel
Weight1.7 kg (with 2m cable); 1.3 kg (with connector)1.4 kg1.7 kg (with 2m cable); 1.3 kg (with connector)
IP ratingIP66 (NEMA4X)IP66 (NEMA4X)IP66 (NEMA4X)
Operating temperature-55°C to +70°C (with heating)-55°C to +70°C (with heating)-55°C to +70°C (with heating)
Heating7 A @ 24 VAC/DC (1 W/cm², approx 150 W)Optional 3A @ 24 VAC/DC7 A @ 24 VAC/DC (1 W/cm², approx 150 W)
Icing standardMIL-STD-810F Method 521.2 Procedure INot statedMIL-STD-810F Method 521.2 Procedure I
Aviation acceptanceFAA and CAA accepted as part of suitable AWOS; meets ICAO Annex 3Not statedNot stated
Output rate1 to 4 Hz1, 2, 4, 5, 8 or 10 Hz1 to 4 Hz
OutputsRS422 / RS485 full or half duplexRS422 / RS485 full or half duplexRS422 / RS485 full or half duplex
WMO complianceRolling average and 3-second gust to WMO No. 8Rolling average and 3-second gust to WMO No. 8Not stated
Power (anemometer only)Not stated9-30 VDC, 30 mA @ 12 VDCNot stated
ProtocolsNot statedModbus RTUNot stated
ParametersNot statedUV, Polar, NMEA, TunnelNot stated
CalibrationNot statedNot statedCalibrated in Merlin Wind Tunnel, traceable to national standards
DatasheetDatasheetDatasheetDatasheet

3D AIRFLOW

Turbulence, structural loading and ventilation

When the up-and-down movement of air matters as well as speed and direction. The choice is wind speed, construction and how the head has to sit.

Best for3D airflow, general useWindMaster3D airflow in high windsWindMaster ProAwkward mounting positionsWindMaster RA
Choose it whenYou need the vertical component as well as the horizontal, for meteorology, structures, wind energy or ventilation.Wind speeds reach 65 m/s or the site is marine, and you want sharper vertical resolution.The installation is restricted or the head has to sit at a non-standard angle.
Wind speed range0 to 50 m/s0 to 65 m/s0 to 50 m/s
Wind speed accuracyUnder 1.5% RMS at 12 m/sUnder 1.5% RMS at 12 m/sUnder 1.5% RMS at 12 m/s
Direction accuracy2° at 12 m/s2° at 12 m/s2° at 12 m/s
Output rate20 Hz standard (32 Hz option)32 Hz standard20 Hz standard (32 Hz option)
OutputsU, V, W, SoS, sonic temperatureU, V, W, SoS, sonic temperatureNot stated
ConstructionAluminium and carbon fibreStainless steelAluminium and carbon fibre
IP ratingIP65IP65IP65
Operating temp-40°C to +70°C-40°C to +70°C-40°C to +70°C
Weight1.0 kg1.7 kg1.0 kg
Digital outputRS232, RS422, RS485RS232, RS422, RS485RS232, RS422, RS485
Analogue outputsOptional (12 or 14 bit, 4 channels)Optional (14 bit, 4 channels; includes PRT input)Optional (12 or 14 bit, 4 channels)
Power9-30 VDC, 55 mA at 12 VDC9-30 VDC, 55 mA at 12 VDC9-30 VDC, 55 mA at 12 VDC
Custom calibrationOptional (wind tunnel test)Optional (wind tunnel test)Optional (wind tunnel test)
W resolutionNot statedImproved vs standard WindMasterNot stated
Head designNot statedNot statedRight-angle
DatasheetDatasheetDatasheetDatasheet

3D AIRFLOW

Flux and eddy covariance research

Very fast readings from a sensor that disturbs the air as little as possible. Two questions decide it: how many readings a second, and which direction of flow matters most.

Best forFlux work, minimal disturbanceWindMaster HSResearch flux at 50 HzR3-50Research turbulence at 100 HzR3-100Horizontal flow at 100 HzR3A-100Vertical flow at 50 HzHS-50Vertical flow at 100 HzHS-100
Choose it whenEddy covariance or offshore work where the sensor itself must disturb the airflow as little as possible.Eddy covariance and turbulence research where 50 readings a second is enough.High-frequency turbulence analysis where 50 Hz is not enough.Horizontal airflow matters most and the sensor should interrupt it as little as possible.Vertical flow matters most, with a stainless body and a built-in inclinometer.As above, but at the highest output rate in the family.
Wind speed range0 to 45 m/s0 to 45 m/s0 to 45 m/s0 to 45 m/s0 to 45 m/s0 to 45 m/s
Wind speed accuracyUnder 1.5% RMS at 12 m/sUnder 1% RMSUnder 1% RMSUnder 1% RMSUnder 1% RMSUnder 1% RMS
Direction accuracy2° at 12 m/sUnder ±1° RMSUnder ±1° RMSUnder ±1° RMSUnder ±1° RMSUnder ±1° RMS
Output rate32 Hz (internal: 20 or 32 Hz)50 Hz (selectable 0.4 to 50 Hz)100 Hz (selectable 0.4 to 100 Hz)100 Hz (selectable 0.4 to 100 Hz)50 Hz (selectable 0.4 to 50 Hz)100 Hz (selectable 0.4 to 100 Hz)
Head designHorizontal (minimal flow disturbance)Not statedNot statedAsymmetric (horizontal flow accuracy)Horizontal (vertical flow accuracy)Horizontal (vertical flow accuracy)
ConstructionStainless steelAluminium and carbon fibreAluminium and carbon fibreAluminium and carbon fibreStainless steelStainless steel
IP ratingIP65IP65IP65IP65IP65IP65
Operating temp-40°C to +70°C-40°C to +60°C-40°C to +60°C-40°C to +60°C-40°C to +60°C-40°C to +60°C
Weight2.96 kg1.0 kgNot stated1.2 kgNot statedNot stated
Digital outputRS232, RS422, RS485RS422 full duplex onlyRS422 full duplex onlyRS422 full duplex onlyRS422 full duplex onlyRS422 full duplex only
Analogue outputsOptional (14 bit, 4 channels)Supplied PCIA unit (7 channels, 14 bit)Supplied PCIA unit (7 channels, 14 bit)Supplied PCIA unit (7 channels, 14 bit)Supplied PCIA unit (7 channels, 14 bit)Supplied PCIA unit (7 channels, 14 bit)
Power9-30 VDC, 55 mA at 12 VDC9-30 VDC (under 150 mA at 24 VDC)9-30 VDC (under 150 mA at 24 VDC)9-30 VDC (under 150 mA at 24 VDC)9-30 VDC (under 150 mA at 24 VDC)9-30 VDC (under 150 mA at 24 VDC)
Custom calibrationOptional (wind tunnel test)Provided as standardProvided as standardProvided as standardProvided as standardProvided as standard
Analogue inputsNot statedOptional SIU (6 differential, 14 bit)Optional SIU (6 differential, 14 bit)Optional SIU (6 differential, 14 bit)6 differential inputs (separate electronic unit)6 differential inputs (separate electronic unit)
InclinometerNot statedNot statedNot statedOptionalBuilt-in (range ±20°, accuracy ±0.3°)Built-in (range ±20°, accuracy ±0.3°)
Accuracy noteNot statedNot statedNot statedApplies for incidence up to ±50° from horizontalNot statedNot stated
DatasheetDatasheetDatasheetDatasheetNot statedDatasheetDatasheet

WEATHER

Full weather monitoring

Wind, temperature, humidity and pressure as a starting point. The choice is what you add: rainfall, rainfall accuracy, sunlight, or sensors mounted apart.

Best forCore weather, no rainGMX500Adds rainfallGMX600Adds the most accurate rainfallGMX603Adds rainfall and sunlightGMX551Sensors mounted apartMetConnect One
Choose it whenWind, temperature, humidity and pressure are enough.You need rainfall as well as core weather.Rainfall accuracy matters, so you want the higher-accuracy optical rain sensor.You want wind, weather, rainfall and solar radiation from one instrument.Sensors need to sit at different heights, or you want to add your own.
Measured parametersWind speed and direction, temperature, humidity, pressureWind, temperature, humidity, pressure, precipitationWind, temperature, humidity, pressure, precipitationWind, temperature, humidity, pressure, solar, precipitationWind, temperature, humidity, pressure (integrated)
Wind range0 to 60 m/s0 to 60 m/s0 to 60 m/s0 to 60 m/sNot stated
Temperature range-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C
Compass2-axis2-axis2-axis2-axisNot stated
GPSOptionalOptionalOptionalOptionalNot stated
HeatingOptional transducer heating (low power)Optional transducer heating (low power)Optional transducer heating (low power)Optional transducer heating (low power)Not stated
IP ratingIP66IP66IP66IP66Hub box IP66 and IP67, sensors IP66
Weight0.7 kg0.8 kg1.1 kg0.8 kgNot stated
OutputsRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUS
PrecipitationNot statedOptical, 0-300 mm/hrHigh-accuracy optical, 0-200 mm/hr, ≤5% accuracyOptical or tipping bucket optionNot stated
Tip sizeNot statedNot stated0.1 mmNot statedNot stated
Solar radiationNot statedNot statedNot stated0-1600 W/m² (ISO 9060 Class C)Not stated
WindNot statedNot statedNot statedNot statedIntegrated WindSonic (0 to 60 m/s)
Extra inputsNot statedNot statedNot statedNot stated2 analogue (0-5V or 4-20mA), 1 PRT (Pt100), 1 rain gauge
ConfigurationNot statedNot statedNot statedNot statedSensors can be placed at different heights
StandardsNot statedNot statedNot statedNot statedWMO-aligned
ConstructionNot statedNot statedNot statedNot stated316 stainless steel hub box and bracket, UV-stabilised polycarbonate sensor housings
DatasheetDatasheetDatasheetDatasheetDatasheetDatasheet

WEATHER

Measuring rainfall

The choice is what else you need to measure alongside rainfall, and how accurate the rainfall reading has to be.

Best forRain and wind onlyGMX240Rain without windGMX400Rain with full weatherGMX600The most accurate rainfallGMX603Rain, sunlight and full weatherGMX551
Choose it whenTemperature and pressure are already measured separately.You need rainfall with temperature, humidity and pressure, and no wind.You need rainfall alongside wind and core weather.Rainfall accuracy matters more than anything else.You want everything from a single instrument.
Measured parametersWind speed and direction, precipitationTemperature, humidity, pressure, precipitationWind, temperature, humidity, pressure, precipitationWind, temperature, humidity, pressure, precipitationWind, temperature, humidity, pressure, solar, precipitation
Wind range0 to 60 m/sNot stated0 to 60 m/s0 to 60 m/s0 to 60 m/s
Wind accuracy±0.3 m/s (0 to 10 m/s); ±3% (10-40); ±5% (40-60)Not statedNot statedNot statedNot stated
PrecipitationOptical, 0-300 mm/hrOptical, 0-300 mm/hrOptical, 0-300 mm/hrHigh-accuracy optical, 0-200 mm/hr, ≤5% accuracyOptical or tipping bucket option
Compass2-axisNot stated2-axis2-axis2-axis
GPSOptionalNot statedOptionalOptionalOptional
HeatingNot statedNot statedOptional transducer heating (low power)Optional transducer heating (low power)Optional transducer heating (low power)
IP ratingIP66IP66IP66IP66IP66
Operating temp-35°C to +70°CNot statedNot statedNot statedNot stated
Weight0.5 kg0.5 kg0.8 kg1.1 kg0.8 kg
OutputsRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUS
Temperature rangeNot stated-35°C to +70°C-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)
Tip sizeNot statedNot statedNot stated0.1 mmNot stated
Solar radiationNot statedNot statedNot statedNot stated0-1600 W/m² (ISO 9060 Class C)
DatasheetDatasheetDatasheetDatasheetDatasheetDatasheet

WEATHER

Measuring sunlight on solar sites

Irradiance on its own, or with the weather that affects panel output.

Best forSunlight onlyGMX301Sunlight and core weatherGMX501Sunlight, rain and full weatherGMX551
Choose it whenYou only need irradiance, for solar monitoring or research.You need irradiance with wind, temperature, humidity and pressure.You also need rainfall.
Measured parametersSolar radiation onlyWind, temperature, humidity, pressure, solar radiationWind, temperature, humidity, pressure, solar, precipitation
Solar radiation0-1600 W/m² (ISO 9060 Class C)0-1600 W/m² (ISO 9060 Class C)0-1600 W/m² (ISO 9060 Class C)
GPSNot statedOptionalOptional
HeatingNot statedOptional transducer heating (low power)Optional transducer heating (low power)
IP ratingIP66IP66IP66
Operating temp-35°C to +70°CNot statedNot stated
Weight0.6 kg0.8 kg0.8 kg
OutputsRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUS
Wind rangeNot stated0 to 60 m/s0 to 60 m/s
Temperature rangeNot stated-35°C to +70°C (-40°C with transducer heating)-35°C to +70°C (-40°C with transducer heating)
CompassNot stated2-axis2-axis
PrecipitationNot statedNot statedOptical or tipping bucket option
DatasheetDatasheetDatasheetDatasheet

WEATHER

Weather on vessels and platforms

Both options have a 6-axis compass and protection against submersion. The choice is wind only, or full weather with true wind calculated on board.

Best forWind on a vesselGMX260Full weather on a vesselGMX560
Choose it whenYou need wind on a moving platform, with a 6-axis compass and protection against submersion.You need wind and weather at sea, with true wind calculated on board.
Measured parametersWind speed and directionWind, temperature, humidity, pressure
Wind range0 to 60 m/s0 to 60 m/s
Compass6-axis (with tilt, pitch, roll)6-axis (with tilt, pitch, roll)
GPSOptionalOptional
HeatingNot statedOptional transducer heating (low power)
IP ratingIP66 and IP68IP66 and IP68
Operating temp-35°C to +70°CNot stated
ConnectorM12 8-way (corrosion-resistant)M12 8-way (corrosion-resistant)
Weight0.5 kg0.7 kg
OutputsRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUS
Temperature rangeNot stated-35°C to +70°C (-40°C with transducer heating)
True windNot statedCalculated on-board
DatasheetDatasheetDatasheet

WEATHER

Weather when you do not need wind

For sites that already measure wind, or do not need it.

Best forAir conditions onlyGMX300Air conditions and rainfallGMX400Room for a wind sensor laterMetConnect THP
Choose it whenYou need temperature, humidity and pressure and do not need wind.You need temperature, humidity, pressure and rainfall, without wind.You want temperature, humidity and pressure now, with inputs for a separate wind sensor or other sensors.
Measured parametersTemperature, humidity, pressureTemperature, humidity, pressure, precipitationTemperature, humidity, pressure (integrated)
Temperature range-35°C to +70°C-35°C to +70°C-35°C to +70°C
Humidity range0-100% RHNot statedNot stated
Pressure range300 to 1250 hPaNot statedNot stated
IP ratingIP66IP66Hub box IP66 and IP67, sensors IP66
Weight0.5 kg0.5 kgNot stated
OutputsRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUSRS232, RS422, RS485, SDI-12, NMEA, MODBUS
PrecipitationNot statedOptical, 0-300 mm/hrNot stated
Wind inputNot statedNot statedSingle M12 connector for remote Gill anemometer
Cold climate optionNot statedNot statedPair with heated WindObserver (full-unit heating) or WindSonic M (100W full-sensor heating)
Extra inputsNot statedNot stated2 analogue (0-5V or 4-20mA), 1 PRT (Pt100), 1 rain gauge
ConfigurationNot statedNot statedSensors can be placed at different heights
StandardsNot statedNot statedWMO-aligned
ConstructionNot statedNot stated316 stainless steel hub box and bracket, UV-stabilised polycarbonate sensor housings
DatasheetDatasheetDatasheetDatasheet

INSIDE THE MACHINE

Knowing how much liquid is in the tank

Fuel, oil, water or coolant, with no moving parts. The choice depends on the liquid and the platform the tank sits in.

Best forWeight-critical tanksLevelLiteIndustrial tanksLevelProDifficult liquidsLevelSlickMilitary platformsLevelDefend
Choose it whenEvery gram counts: motorsport and other weight-critical platforms.Process control, transport, power generation, marine or off-highway machines.The liquid is difficult to measure and electrically conductive.The platform is a defence vehicle or military marine craft.
Measurement typeCapacitive, continuousCapacitive, continuousConductive, continuousCapacitive, continuous
Accuracy±1% at 50% FSD, 20°C±2% FSD at 20°CNot stated±2% FSD at 20°C
Probe length100 to 750 mm in 1 mm steps100 to 2000 mm in standard increments250, 350, 450, 600, 800, 1000, 1500 or 2000 mmBuilt to order
Operating temperature-40°C to +125°C (see derating graph)-40°C to +125°C (see derating graph)-40°C to +85°C (without cable)-40°C to +125°C
Ingress protectionIP68Not statedIP66 / IP68 / IP69K to EN60529IP67
Pressure10 bar absolute and differential10 bar differential and absolute10 bar differential, 5 bar absoluteTo customer requirement
Supply voltage5 to 32 V DC5 to 32 V DC (voltage), 9 to 32 V DC (current)+6 to +32 V DC18 to 32 V DC
Supply current<20 mANot stated15 to 40 mA depending on typeNot stated
Primary output0.25 to 4.75 V standard, 0.25 to 10 V maximum0.25 to 4.75 V factory set, 0.25 to 10 V maximum, or 4 to 20 mA0.25 to 4.75 V DC, 4 to 20 mA, or resistive4 to 20 mA (3 wire plus V, signal and ground)
Secondary outputSwitched (open collector 50 V / 1 A) or temperatureSelectable high/low alarmOpen collector 50 V / 0.5 A max switch to groundNot stated
Resolution10 bit10 bit12 bit (4096 points over measurement range)10 bit
Sample rate100 HzNot statedNot statedNot stated
Data interfaceRS232, configuration onlyRS232, configuration only (adaptor required)Micro USB, sensor mountedRS232
Construction6082 grade aluminium, sealed electronicsStainless steel 316, FEP, PEIStainless steel 316, FEP, EDPMAnodised aluminium 6082 T6, FEP, M3 earth stud
Mounting1, 2, 3, 5 hole and M22 x 1.5 threadedSAE 5-bolt, 1.125in UNF, 1.25in BSP threaded, 2in NPT1.25in BSP threadSAE 5-bolt
Weight48 g at 100 mm probe, plus 0.256 g/mmNot statedNot statedFrom 300 g depending on length
ATEXNot designed or certified for ATEXNot statedNot statedNot designed or certified for ATEX
LinearityNot stated±2% FSD at 20°CNot stated±2% FSD at 20°C
Report rateNot stated100 HzNot stated80 Hz
HumidityNot stated93% RH at 40°CNot statedNot stated
SealsNot statedFluorosilicone O-rings or Klingersil gasket (excluding NPT)Not statedAxial 3 mm Viton O-rings
Output update rateNot statedNot stated10 Hz (0 to 10 V), 100 Hz (resistive)Not stated
Corrosion resistanceNot statedNot statedMarine grade stainless steel 316Not stated
VentingNot statedNot statedVented tanks onlyNot stated
EMCNot statedNot statedEN60945 marine, EN61000-6-2/6-3, EN61326-2-1Not stated
StandardsNot statedNot statedNot statedNot stated
DatasheetDatasheetDatasheetDatasheetDatasheet

INSIDE THE MACHINE

Knowing exactly where a moving part is

Non-contact sensing, so nothing wears out. The choice depends on how far the part moves and whether it slides or rotates.

Best forShort travel, up to 25 mmBlade25Long travel, up to 60 mmBlade60Full rotationBlade360Two independent outputsBlade Dual Output
Choose it whenThe part moves up to 25 mm in a line, or up to 90° around a point.The part moves up to 60 mm in a line, or up to 90° around a point.The part rotates, through up to a full 360°.You need one or two output channels from a single sensor.
MeasurementLinear ±12.5 mm configurable, angular ±45° configurableLinear ±30 mm configurable, angular ±45° configurable0 to 360° configurableRotary ±45°, linear range governed by activator shape
Range accuracy±0.1 mm or equivalent±0.1 mm or equivalent±0.5% FS over temperature range±3% over full temperature range
OutputAnalogue 0 to 5.6 V, PWM 250 Hz or 1 kHz, RS232 / RS485 optional, switchAnalogue 0 to 4.2 V, PWM 250 Hz or 1 kHz, RS232 19.2K 8N, switchAnalogue 0 to 5.5 V, PWM 1 kHz, RS485 19.2K 8N, switchSingle analogue, single 5 V ratiometric, or dual analogue
Supply voltage4.8 to 32 V DC4.8 to 30 V DC4.8 to 32 V DC6 to 30 V DC
Supply current<10 mA with comms<10 mA with comms<25 mA without comms<10 mA
Over voltage protection>33 V DC>31 V DC>33 V DC>31 V DC
Reverse polarity protectionUp to -32 V DCUp to -30 V DCUp to -32 V DCTo -30 V DC
Resolution10 bit over configured range10 bit over configured range10 bit over configured range10 bit
Sample rate1 kHz1 kHz1 kHz1 kHz
Rise time2 ms2 ms2 msNot stated
Ingress protectionIP67IP67IP67IP67
Operating temperature-40°C to +85°C at 32 V DC max, -40°C to +125°C optional at 14 V DC max-40°C to +85°C standard, -40°C to +125°C optional-40°C to +85°C at 32 V DC max, -40°C to +125°C at 14 V DC max-40°C to +85°C standard (see FLAGS)
Size6 x 40 × 50 mm (D x W x L)6 x 77 × 32.5 mm (D x W x L)16 mm x Ø38 mm19 x 25.5 × 64 mm (D x W x L)
Sensor to activator clearance0.5 to 2 mm0.5 to 2 mm0.5 to 2 mm, concentricity <0.5 mmNot stated
Mounting2 x Ø4 mm holes on a 30 mm pitch2 x Ø4 mm holes on a 65.5 mm pitch3 x M3 screws, 0.25 Nm maximum torque2 x Ø4 mm holes on a 30 mm pitch
Weight21.0 g excluding cable25.6 g excluding cable22.8 g excluding cable34 g
Dither lifeNon-contact, no deterioration through useNot statedNot statedNon-contact, no deterioration through use
Switch outputNot statedSwitch to ground, 30 V DC max, 8 mANot statedNot stated
Error levelNot statedNot stated0.3 V default, configurableNot stated
Output rangeNot statedNot statedNot statedSingle channel 0 to 4.3 V at 5 V supply, 0 to 4.5 V at 6 V
DatasheetDatasheetDatasheetDatasheetDatasheet

INSIDE THE MACHINE

Spotting wear before it becomes a failure

Metal debris in lubricating oil is the early warning. The main difference between the two is where you read the result.

Best forWear read by the systemWearDetectWear read at the machineWearDetect with display
Choose it whenYou want wear debris reported continuously to the control system.You also need to read the result at the equipment itself.
MeasuresFine debris, coarse debris, oil status, oil probe temperatureFine debris, coarse debris, water or temperature channel
Over voltage protection>32 V DC>32 V DC
Reverse polarity protectionTo -32 V DCTo -32 V DC
Analogue output0.25 to 10 V DC or 4 to 20 mA, configurableThree channels, 0.25 to 10 V DC or 4 to 20 mA, configurable
Digital outputCAN J1939 (PGN 130816) or Modbus RTU RS-485 half duplexCAN J1939 (PGN 130816), 8 byte data length
Analogue resolution10 bit10 bit
Report rate10 Hz analogue, 1 Hz digital10 Hz analogue, 1 Hz digital
Sensor configurationUSBUSB, Gill software
Sensor size57 x Ø24.5 mm57 x Ø24.5 mm
Sensor protectionIP66 / IP68IP66 / IP68
Enclosure protectionIP65IP65
Differential pressure10 bar10 bar
Operating temperature-26°C to +150°C sensor, +85°C enclosure-26°C to +150°C sensor, +85°C enclosure
Humidity95% RH at +55°C95% RH at +55°C
MaterialsStainless steel, FEP, PEI (sensor); aluminium alloy, stainless steel, polyester (enclosure)Not stated
Mounting threadsM22 x 1.5, M24 x 2.0, 3/4in x 16 UNFM20 x 1.5 and others, contact Gill
ATEXNot designed or certified for ATEXNot designed or certified for ATEX
DatasheetDatasheetDatasheet

INSIDE THE MACHINE

Ignition for gas engines

Chosen by cylinder count and engine size.

Best forIgnition, up to 12 cylindersGS12Ignition, up to 6 cylindersGT6
Choose it whenYou need ignition for a gas engine with up to 12 cylinders and per-cylinder timing.You need compact ignition for a gas engine with up to 6 cylinders, up to 13 litres.
Number of cylinders1 to 121 to 6
Power12 / 24 V DC, 5 A12 / 24 V DC, 5 A
Spark duration500 to 3000 µs continuous500 to 1500 µs continuous
Maximum RPM40004000
TimingGlobal, individual cylinder, dual fuelGlobal, dual fuel
Timing maps2D speed and timing, or 3D speed, timing and load, 5 mapsNot stated
Trigger methodsSingle pickup, OEM disc and pickup, A3 or A5 conversion kit, GM distributor timing kit, drilled flywheel patternGill timing disc and standard pickup, OEM cam disc, A5 conversion kit, drilled flywheel pattern for wasted spark
CommunicationsRS232, DB9 femaleRS232, DB9 female
SoftwareWindows based, multi-level security versionsWindows based GillFire, multi-level security versions
FeaturesTach output signal, shutdown ground, fuel valve sequencingTach output signal
Visual features3 integrated LED status indicatorsIntegrated LED lights
ApplicationAll horsepower and engine sizes, up to 2 coils per cylinderEngines up to 13 L (800 in³)
Environmental-40°C to +90°C, sealed to IP67-40°C to +90°C, sealed to IP67
FuelsNot statedNatural gas, propane, LPG, landfill, digester and other biogas
DatasheetDatasheetDatasheet

ONE ANSWER

Problems with a single answer

Nothing to compare here: for these jobs Gill makes one product, so it is the answer.

Hazardous areas

Offshore oil and gas platforms, petrochemical plants and other explosive atmospheres need an intrinsically safe, ATEX, IECEx and UKEX certified sensor.

The answer: WindObserver IS

Worker heat stress

Assessing heat stress for people working outdoors, with WBGT and Thermal Work Limit calculated in the sensor.

The answer: GMX552

Air/fuel mixture on a gas engine

Holding lambda to a set point on a static gas engine, stoichiometric with a three way catalyst or lean burn.

The answer: AF120

Catch tank oil in endurance racing

Oil level in the catch tank, currently specific to the ACO ELMS race series.

The answer: Catch tank sensor

Showing the tank level

A 29 LED display for a Gill level sensor, with tank profiling for irregular shapes and a low level warning.

The answer: DD1615 display

Have an application to discuss?

Speak to our team

Tell us what you need to measure, where and under what conditions. We’ll help you work out the appropriate approach.

  • Our team replies. Not an account manager, and not a queue.
  • We aim to respond in one working day. Monday to Friday.
  • No obligation. Just honest advice on whether Gill is the right fit.